ABS AFP 0831S Installation And Operating Instructions Manual

Submersible sewage pump

Advertisement

ABS submersible sewage pump AFP 0831S and 0841S
Installation and Operating Instructions
GB
www.absgroup.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AFP 0831S and is the answer not in the manual?

Questions and answers

Summary of Contents for ABS AFP 0831S

  • Page 1 ABS submersible sewage pump AFP 0831S and 0841S Installation and Operating Instructions www.absgroup.com...
  • Page 2: Table Of Contents

    Commentary on maintenance of lifting stations in accordance with EN 12056........11 Oil filling and oil changing ........................11 Cleaning ..............................11 Venting of the volute ..........................11 Declaration of Conformity ..........................13 ABS reserves the right to alter specifications due to technical developments...
  • Page 3: General

    ATTENTION The maximum allowable temperature of the medium pumped is 40 °C The ABS submersible sewage pumps of the AFP series have been designed for the economic and reliable pumping of commercial, industrial and municipal sewage and can be installed dry or wet. They are suitable for pumping of the following liquids:...
  • Page 4: Safety

    Standard version nameplate Safety The general and specific Health and Safety requirements are described in detail in the Safety Instructions for ABS Products booklet. If anything is not clear or you have any questions as to safety make certain to contact the manufacturer ABS. Transport During transport the unit should not be dropped or thrown.
  • Page 5: Setup And Installation

    Installation and Operating Instructions ABS submersible sewage pump AFP 0831S and 0841S Setup and installation ATTENTION All relevant regulations covering sewage pumping installations and, where applicable, explosion-proof installations must be complied with. The cable duct to the control panel should be made gas-tight by filling with foam after the power supply and control circuit cables have been laid. Particular attention must be paid to the safety regulations covering work in closed areas in sewage plants as well as good general technical practices .
  • Page 6: Electrical Connection

    Installation and Operating Instructions ABS submersible sewage pump AFP 0831S and 0841S .3 Electrical connection Before commissioning an expert should check that one of the necessary electrical protective devices is available. Earthing, neutral, earth leakage circuit breakers, etc. must comply with the regulations of the local electricity supply authority and a qualified person should check that these are in perfect order.
  • Page 7: Checking Direction Of Rotation

    Installation and Operating Instructions ABS submersible sewage pump AFP 0831S and 0841S .3.2 Checking direction of rotation The safety hints in the previous sections must be observed! When three phase units are being commissioned for the first time and also when used on a new site, the direction of rotation must be carefully checked by a qualified person.
  • Page 8: Commissioning

    Lubricated-for-life ball bearings together with monitoring devices ensure optimum pump reliability provided that the pump has been connected and operated in accordance with the operating instructions. Should, nevertheless, a malfunction occur, do not improvise but ask your ABS customer service department for assistance.
  • Page 9: Commentary On Maintenance Of Lifting Stations In Accordance With En 12056

    Installation and Operating Instructions ABS submersible sewage pump AFP 0831S and 0841S NOTE The ABS service organisation would be pleased to advise you on any applications you may have and to assist you in solving your pumping problems. NOTE The ABS warranty conditions are only valid provided that any repair work has been carried out in ABS approved workshop and where original ABS spare parts have been used. 6.2 Commentary on maintenance of lifting stations in accordance with EN 12056. It is recommended that the lifting station be inspected monthly and its function checked. In accordance with EN regulations, the lifting station should be maintained by a qualified person at the following intervals: •...
  • Page 10 Installation and Operating Instructions ABS submersible sewage pump AFP 0831S and 0841S...
  • Page 11: Declaration Of Conformity

    IT: Dichiarazione di conformità PL: Deklaracja zgodnosci SK: Vyhlásenie o zhode Uygunluk beyanı ABS Production Wexford Ltd, Clonard Road, Wexford, Ireland GB: Declare under our sole responsibility that the products DK: Erklærer på eget ansvar, at følgende produkter DE: Erklärt eigenverantwortlich, daß die Produkte Vakuutamme yksinomaan omalla vastuullamme, että seuraavat tuotteet FR: Déclarons sous notre seule responsabilité que les produits...
  • Page 12 ABS Production Wexford Ltd., Clonard Road, Wexford, Ireland Tel. +353 53 91 63 200 Fax +353 53 91 42335. www.absgroup.com...

This manual is also suitable for:

Afp0841s

Table of Contents