Parameter List (Zs-Hldc) - Omron ZS Command Reference Manual

Smart sensors compoway/f communication
Hide thumbs Also See for ZS:
Table of Contents

Advertisement

Parameter List (ZS-HLDC)

Sensing Setting (common for all TASKs)
Unit No.
Data No.
0h
0h
Measurement mode
Measurement mode
Ch
Start position of area 1
Eh
End position of area 1
Dh
Start line of area 1
Fh
End line of area 1
18h
Start position of area 2
1Ah
End position of area 2
19h
Start line of area 2
1Ah
End line of area 2
12h
Exposure time
13h
Number of additional
lines
14h
Line skipping
16h
2-area mode
17h
Compensation mode
20h
Measurement cycle
C0h
Reference point teach for
compensation mode
C1h
2-area teach
1h
0h
Head installation
2h
0h
LD power mode
Setting Value Obtaining and Changing Command
Parameter
Setting range/output range
0: STANDARD
1: HI-RESO
2: HI-SPEED
3: HI-SENS
4: CUSTOM
1: STANDARD
2: HI-RESO
3: HI-SENS
4: CUSTOM
0 to 639 (pix)
0 to 639 (pix)
0 to (Number of additional lines -
1)
0 to (Number of additional lines -
1)
0 to 639 (pix)
0 to 639 (pix)
0 to (Number of additional lines -
1)
0 to (Number of additional lines -
1)
2 to 200 (1div:0.1ms)
When multi-task mode is OFF
5 to 200 (1div:0.1ms)
When multi-task mode is ON
1 to 200
When multi-task mode is OFF
8 to 200
When multi-task mode is ON
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: Start position compensation
2: End position compensation
3: Start/end position compensation
112 to 20000 (us)
1: Execute teach
1: Execute teach
0: Diffuse
1: Regular
0: Auto
1: Auto-scale
2: Fixed
CompoWay/F Communication Command Reference
Section 3
Remarks
When multi-task
mode is OFF
When multi-task
mode is ON
Parameters for
CUSTOM mode
3-11
ZS Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu

Table of Contents