Omron ZS Command Reference Manual page 48

Smart sensors compoway/f communication
Hide thumbs Also See for ZS:
Table of Contents

Advertisement

Section 3
Setting Value Obtaining and Changing Command
Unit No.
Data No.
(Note 1)
02h
2Ch
03h
2Dh
02h
03h
04h
05h
06h
07h
08h
2Eh
05h
07h
30h
02h
03h
(Note 1)
The Unit No. here indicates TASK 1 Unit No.
Unit No. other than the above, such as TASK2 or a later one, can be calculated by adding (TASK
number -1) to the Unit No. and multiplying it by 14h for another reference or setting.
Example 1: When reading the setting values of the average number of times for TASK 1:
Since the average number of times is 2Bh for Unit No., and 02h for Data No., values are shown as
below:
02h 01h (C000h + 02h (Data No.)) 2Bh (Unit No.) 00h (CH No.) (8000h + 1h (Number of elements))
In the command section, the value is shown as below:
02h 01h C002h 2B00h 8001h
To this command, if the response is shown as below:
02h 01h C002h 2B01h 8001h 00000004h
Since the value is 4, this indicates 16 times.
ZS Series
3-22
CompoWay/F Communication Command Reference
Parameter
Differential mode
Differentiation cycles
Hold mode
Trigger method
Trigger level
Trigger hysteresis
Trigger delay (ms)
Sampling period (ms)
Trigger delay mode
Offset value for zero
reset
Zero reset mode
LOW threshold value
HIGH threshold value
Setting range/output
range
0: OFF
1: ON
1 to 5000 (ms)
0: OFF
1: PEAK
2: BOTTOM
3: P-P
4: AVERAGE
5: SAMPLE
0: External
1: Self-up trigger
2: Self-down trigger
-999999999 to
999999999 (nm)
0 to 999999999 (nm)
0 to 5000 (ms)
1 to 5000 (ms)
0: OFF
1: ON
-999999999 to
999999999 (nm)
0: REAL
1: HOLD
-999999999 to
999999999 (nm)
-999999999 to
999999999 (nm)
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu

Table of Contents