Section 3
Setting Value Obtaining and Changing Command
Measurement Setting 2 (common to all TASKs)
Unit No.
Data No.
78h
00h
01h
79h
00h
01h
02h
7Ah
02h
03h
04h
05h
06h
07h
08h
7Dh
04h
05h
06h
07h
7Eh
00h
01h
02h
ZS Series
3-24
CompoWay/F Communication Command Reference
Parameter
Non-measurement
settings
Output upon clamp
HYS
Timer mode
Delay time
Monitor focus mode
Monitor focus distance
value 1
Monitor focus distance
value 2
Monitor focus current
value 1
Monitor focus current
value 2
Monitor focus voltage
value 1
Monitor focus voltage
value 2
Input polarity of external
input 0
Input polarity of external
input 1
Input polarity of external
input 2
Input polarity of external
input 3
External input (IN)
External Input (IN)
function mode
External output (OUT)
Setting range/ output range
0: Keep
1: Clamp
0: MAX
1: 20mA
2: 12mA
3: 4mA
4: MIN
0 to 999999999 (nm)
0: OFF
1: OFF DELAY
2: ON DELAY
3: 1 shot
1 to 5000 (ms)
0: OFF, 1: ON
-999999999 to 999999999 (nm)
-999999999 to 999999999 (nm)
4 to 20 (mA)
4 to 20 (mA)
-10 to 10 (V)
-10 to 10 (V)
0: L active
1: H active
0: None
1: TASK 1
2: TASK 2
3: TASK 3
4: TASK 4
5: TASK ALL
0: Standard
1: Bank
0: None
1: TASK 1
2: TASK 2
3: TASK 3
4: TASK 4
Remarks
(Note 2)