Measurement Result Obtaining Command - Omron ZS Command Reference Manual

Smart sensors compoway/f communication
Hide thumbs Also See for ZS:
Table of Contents

Advertisement

Section 3

Measurement Result Obtaining Command

Measurement Result Obtaining Command

Parameter List (ZS-LDC)
When selecting a mode other than "THICK/GAP - FILM/OTHERS - TRANSFER" mode
(when no 2-area measurement is performed):
Unit No.
Data No.
30h
20h
When selecting "THICK/GAP - FILM/OTHERS - TRANSFER" mode
(when a 2-area measurement is performed):
Unit No.
Data No.
30h
44h
20h
58h
Parameter List (ZS-HLDC)
For single task mode
When selecting a mode other than "GLASS/MODE 2" or "GLASS THICKNESS/MODE 2"
mode
(when no 2-area measurement is performed):
Unit No.
Data No.
30h
20h
When selecting "GLASS/MODE 2" or "GLASS THICKNESS/MODE 2" mode
(when a 2-area measurement is performed):
Unit No.
Data No.
30h
44h
20h
58h
For multi-task mode
Unit No.
Data No.
30h
44h
20h
58h
6Ch
ZS Series
3-2
CompoWay/F Communication Command Reference
Parameter Description
Measurement result (=Main digital display value)
Parameter
Area 1 displacement value (TASK1)
Area 2 displacement value (TASK2)
Thickness and/or Gap results
(=Main digital display value = TASK3 = Area1 –
Area2)
Parameter Description
Measurement result (=Main digital display value)
Parameter
Area 1 displacement value (TASK1)
Area 2 displacement value (TASK2)
Glass surface and/or Glass thickness results
(=Main digital display value = TASK3 = Area1 –
Area2)
Parameter
TASK1 measurement result
TASK2 measurement result
TASK3 measurement result
TASK4 measurement result

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu

Table of Contents