Section 3

Setting Value Obtaining and Changing Command

Setting Value Obtaining and Changing Command

Parameter List (ZS-LDC)

Sensing Setting (common for all TASKs)
Data
Unit No.
No.
00h
00h
12h
13h
14h
01h
00h
02h
00h
02h
06h
0Dh
0Eh
25h
26h
27h
03h
00h
01h
02h
ZS Series
3-4
CompoWay/F Communication Command Reference
Parameter
Measurement mode
Exposure time
Number of additional
lines
Line skipping
Head installation
LD power mode
Surface to be controlled
for light amount
LD power when fixed
Lower limit of LD power
Upper limit of LD power
Incident level
(First surface)
Incident level
(Second surface)
Incident level
(Third surface)
Measurement object
Glass material
Glass thickness
measurement mode
Setting range/
output range
0: STANDARD
1: HI-RESO
2: HI-SPEED
3: HI-SENS
4: CUSTOM
2 to 200
Parameters when
(1div:0.1ms)
[Measurement mode]=[Custom]
1 to 200
0: ON
1: OFF
0: DIFFUSE
1: REGULAR
0: Auto
(Note 1)
1: Auto range
2: Fixed
0: Peak
1: Surface
2: Second surface
3: Third surface
0 to 1000
Parameters when [Emitted light
(1div:0.1%)
amount setting]=[Fixed]
0 to 800
Parameters when [Emitted light
(1div:0.1%)
amount setting]=[Auto range]
0 to800
(1div:0.1%)
0 to 4095 (tone)
0 to 4095 (tone)
0 to 4095 (tone)
0: NORMAL
1: PCB
2: MIRROR
3: GLASS
4: THICKNESS
5: GAP
0: NORMAL
Parameters when
1: FILM/OTHERS
[Measurement
object]=[Thickness] or [Gap]
0: STOP
Parameters when [Glass
1: Moving
material]=[FILM/ OTHERS]
Remarks