13
Response
MRC
SRC
"30"
"05"
2 bytes
2 bytes
Elements
Response Code
Instruction Code
Related Information 1
Related Information 2
Response code for normal end
Response Code
"0000"
Normal end
Response code when an error occurs
Response Code
"1001"
Long command length
"1002"
Short command length
"1101"
Area type error
"1103"
Start address outside of range
error
"2203"
Operating error
"2204"
Operating error
"2205"
Operating error
Instruction
Response Code
Code
4 bytes
2 bytes
Indicates controller status for the command.
The code which is the same as the transmitted will be returned.
Name
No errors.
Error Name
Command length is too long.
Command length is too short.
Instruction code is invalid.
Related information specifies the sensor of the
unconnected Machine No.
Setting is abnormal.
Refer to the User's Manual of the ZS Series for error
conditions.
Operating mode of sensor is other than RUN.
Invalid command.
Operation Instructions
Related
Related
Information 2
Information 1
2 bytes
4 bytes
Details
Details
Cause
CompoWay/F Communication Command Reference
Section 2
2-13
ZS Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu