DeviceNet Communications Cables Wiring

1,2,3...
Molded transformer
Extraction tool
Fig. 1
sponding connector holes, as shown in the following diagram.
1: V− (Power line: black)
2: CAN low (Communications line: blue)
3: Shield
4: CAN high (Communications line: white)
5: V+ (Power line: red)
Make sure that the connector is oriented correctly before inserting the
crimp terminal into the connector, as shown in the following diagram.
The crimp terminals can be crimped using a crimp tool that conforms to JIS
C9711. The following crimp tool is also available:
HR31-TC-01 (Hirose Electric)
If wiring is not correct, use an extraction tool to extract the wires using the fol-
lowing procedure.
1. Press down the molded transformer using the extraction tool, as shown in
Fig. 1.
2. While keeping the molded transformer pressed down, tilt the extraction tool
to release the crimp terminal lock.
3. Remove the extraction tool.
4. Pull the cable and pull out the crimp terminal.
Power line
Extraction tool
The following extraction tool is available:
HR31-SC-TP (Hirose Electric)
Crimp terminal
Molded transformer
Fig. 2
Section 3-2
Power line
Power line
5-5