Omron K3HB - MANUAL 2 Manual page 55

Digital indicators
Hide thumbs Also See for K3HB - MANUAL 2:
Table of Contents

Advertisement

List of Settings
Communications Setting Level
Variable
Address
Parameter
type
name
CA
0000
Unit No.
0001
Baud rate
0002
Data length
0003
Stop bit
length
0004
Parity
0005
Send wait
time
Note The values beginning with H' in the Monitor/Setting range column are used when setting or monitoring
data via communications.
Advanced Function Setting Level
Variable
Address
Parameter
type
name
CB
0000
PASS-output
change
0001
Hysteresis
0002
Output OFF
delay
0003
Shot output
0004
Output logic
0005
Output
refresh stop
0006
Tare zero
0007
Zero trim-
ming
0008
Previous
average
value com-
parison
0009
Bank selec-
tion
000A
Startup com-
pensation
timer
000B
Input error
enable
000C
Standby
sequence
000D
Cold junction
compensat-
ing circuit
Note (1) The values beginning with H' in the Monitor/Setting range column are used when setting or monitoring
data via communications.
(2) If the event connector is provided as a standard feature or an event connector is added, use EV for
the "bank selection" setting.
2-10
Character
Monitor/Setting range
u-no H'00000000 to
H'00000063: (0 to 99)
bps H'00000000: 9.6(0),
H'00000001: 19.2(1),
H'00000002: 38.4(2)
len H'00000000: 7(0),
H'00000001: 8(1)
sbit H'00000000: 1(0),
H'00000001: 2(1)
prty H'00000000: None (0),
H'00000001: Even (1),
H'00000002: Odd (2)
sdwt H'00000000 to
H'00000063 (0 to 99)
Charac-
Monitor/Setting range
ter
pass H'00000000: LL(0), H'00000001:
L(1), H'00000002: PASS(2),
H'00000003: H(3), H'00000004:
HH(4), H'00000005: ERR(5)
hys H'00000000 to
H'0000270F: (0 to 9,999)
off-d H'00000000 to
H'000007CF (0 to 1,999)
shot H'00000000 to
H'000007CF (0 to 1,999)
out-n H'00000000: Close in alarm(0),
H'00000001: Open in alarm(1)
o-stp H'00000000: OFF(0), H'00000001:
OUT(1), H'00000002: ALL(2)
t-zr H'00000000: OFF(0)
H'00000001: ON(1)
z-trm H'00000000: OFF(0)
H'00000001: ON(1)
hp-f H'00000000: OFF(0)
H'00000001: ON(1)
bnk-c H'00000000: OFF(0), H'00000001:
KEY(1), H'00000002: EV(2)
s-tmr H'00000000 to
H'0000270F: (0 to 99.9)
s.err H'00000000: Disable(0),
H'00000001: overflow(1),
H'00000002: input error(2)
stdby H'00000000: OFF(0)
H'00000001: ON(1)
cjc H'00000000: OFF(0)
H'00000001: ON(1)
Character
Default
Decimal
setting
point
0 to 99
1
---
9 . 6, 19 . 2,
9 . 6
---
38 . 4
7, 8
7
---
1, 2
2
---
none, even,
even
---
odd
0 to 99
20
---
Character
Default
Decimal
setting
ll, l, pass,
pass
---
h, hh, err
0 to 9999
1
According to
the decimal
position set-
ting
0 to 1999
0
---
0 to 1999
0
---
n-o, n-c
n-o
---
off, out, all off
---
off, on
off
---
off, on
off
---
off, on
off
---
off, key, ev
off
---
(See note.)
0 . 0 to 99 . 9
0 . 0
1
off, over,
s.err
---
s.err
off, on
off
---
off, on
on
---
Section 2
Unit
Model
X
V
S
H
---
kbps
bit
bit
---
ms
Unit
Model
point
X
V
S
H
---
---
S: ms
Others:
100 ms
S: ms
Others:
100 ms
---
---
---
x
---
x
---
---
s
---
---
---
x
x
x

Advertisement

Table of Contents
loading

Table of Contents