Parameters
Characters
ra1
Control Output 1 ON/
OFF Count Alarm
Set Value
ra2
Control Output 2 ON/
OFF Count Alarm
Set Value
rac
ON/OFF Counter
Reset
cmov
Move to Calibration
Level
Note
(1) Set "None" as the unit for analog inputs (23: 0 to 50 mV).
(2) The setting range depends on whether control output 1 is a current output or voltage output (for driv-
ing SSR).
(3) P.END (program end output) can be set even when the program pattern is set to OFF, but the func-
tion will be disabled.
(4) Turns ON when either the control output 1 or 2 ON/OFF count alarm is ON.
(5) Displayed when logic operations are used. For detail, refer to 4-22 Logic Operations.
Protect Level
Parameters
Move to Protect level
Operation/Adjustment Protect
Initial Setting/Communica-
tions Protect
Setting Change Protect
PF Key Protect
Parameter Mask Enable
Password to Move to Protect
Level
Communications Setting Level
Parameters
Protocol Setting
Communications Unit No. u-no
Communications Baud
Rate
Communications Data
Length
Communications Stop
Bits
Communications Parity
Send Data Wait Time
Note When setting CWF, either CompoWay/F or SYSWAY can be used as the communications protocol.
(CompoWay/F and SYSWAY are automatically identified by the command frames.)
Setting (monitor) value
0 to 9999
0 to 9999
0: Disable the counter reset
function.
1: Reset the control output 1
ON/OFF counter.
2: Reset the control output 2
ON/OFF counter.
1999 to 9,999
Characters
Setting (monitor) value
pmov
1999 to 9,999
oapt
0 to 3
icpt
0 to 2
wtpt
OFF, ON
pfpt
OFF, ON
pmsk
OFF, ON
prlp
1999 to 9,999
Characters
Setting (monitor) value
psel
CompoWay/F (SYSWAY),
Modbus (See note.)
0 to 99
bps
1.2, 2.4, 4.8, 9.6, 19.2, 38.4,
or 57.6
len
7, 8
sbit
1, 2
prty
None, Even, Odd
sdwt
0 to 99
Display
Default
0
100 times
0
100 times
0
None
0
None
Display
Default
0
0
1
off, on
OFF
off, on
OFF
off, on
ON
0
Display
Default
cwf, mod
Compo-
Way/F
(SYSWAY)
1
1.2, 2.4,
9.6
4.8, 9.6,
19.2, 38.4,
57.6
7
2
none,
Even
even, odd
20
Appendix
Unit
Set value
Unit
Set value
None
None
None
None
None
None
None
Unit
Set value
None
None
kbps
Bit
Bit
None
ms
299