Executing Heating/Cooling Control
Example: E5CN
Parameter name
Symbol
out1
Control Output 1
Assignment
out2
Control Output 2
Assignment
sub1
Auxiliary Output 1
Assignment
sub2
Auxiliary Output 2
Assignment
Example: E5GN
Parameter name
Symbol
out1
Control Output 1
Assignment
sub1
Auxiliary Output 1
Assignment
sub2
Auxiliary Output 2
Assignment
Note
96
The following functions are assigned to outputs in the initial status.
Parameter name
Control Output 1 Assignment
Control Output 2 Assignment
Auxiliary Output 1 Assignment
Auxiliary Output 2 Assignment
Auxiliary Output 3 Assignment
(E5AN/EN only)
Each output assignment is automatically initialized as shown below when the
control mode is changed.
Without control output 2
Standard
Heating/cooling
Control output
Control output
(heating)
(heating)
Not assigned. (See
Not assigned. (See
note 1.)
note 1.)
Alarm 1 (See note
Alarm 1 (See note
2.)
2.)
Alarm 2 (See note
Control output (coo-
3.)
ing) (See note 3.)
Standard
Heating/cooling
Control output
Control output
(heating)
(heating)
Alarm 1 (See note
Control output (coo-
2.)
ing)
Alarm 2
Alarm 2
(1) No parameter assignment is displayed because there is no control output
2.
(2) The output set for the Auxiliary Output 1 Assignment parameter becomes
the program END output unless the program pattern is OFF.
(3) For the E5AN/EN, the Auxiliary Output 3 Assignment parameter is set for
control output (cooling) (the Auxiliary Output 2 Assignment parameter is
set for alarm 2).
• The heating/cooling operation of the control outputs will switch when the
Direct/Reverse Operation parameter is set to "direct."
• When DRS (Invert Direct/Reverse Operation) is assigned for an Event
Input Assignment (1 or 2), control will start with the contents set for the
Direct/Reverse Operation parameter inverted when the event input turns
ON, and with the contents left according to the setting when the event
input turns OFF. For details on event inputs and control combined with the
Direct/Reverse Operation parameter, refer to Control by Inverting Direct/
Reverse Operation on page 103.
• When heating/cooling control is selected, the Dead Band and Cooling
Coefficient parameters can be used.
Symbol
Initial status
out1
Control output for heating
out2
Not assigned.
sub1
Alarm 1
sub2
Alarm 2
sub3
Alarm 3
With control output 2
Standard
Control output
(heating)
Not assigned.
Alarm 1 (See note
2.)
Alarm 2
Section 4-4
Heating/cooling
Control output
(heating)
Control output (coo-
ing)
Alarm 1 (See note
2.)
Alarm 2