Korg NAUTILUS 61 AT Operation Manual page 143

Table of Contents

Advertisement

14.Press the EXIT button, and then press the Recording
tab to go to the Recording– Recording page.
15.Select Index.
If you want to create a new index, press the Create
button.
Set the recording level
16.Refer to "Set the recording level" on page 135 to make
the settings.
Record
Press the SAMPLING REC button, and then the
SAMPLING START/STOP button to enter record-ready
mode.
Speak the word you want to sample.
Recording will start when the level exceeds the Level
–30 dB setting.
Press the SAMPLING START/STOP button to stop
sampling.
Hear the sampled result
17.Play the keyboard.
Press the "OrigKey" key to hear the sound you sampled.
Applying an insert effect to a sample and
resampling the result
You can process a sample through effects, and then sample
the result. This is called "resampling." During resampling,
the NAUTILUS can even play a selected source sample
automatically.
"Resample" Auto
1. On the "Recording– Recording" page, assign the
samples to be resampled to "Sample Select".
When the power of the NAUTILUS is first turned on, the
assigned sample will be set to "Orig. Key" (C2).
2. Select the "Auto Sampling Setup" page menu
command.
A dialog box will appear.
3. Select "Auto Resample through IFX", and select an
effect that uses "IFX".
4. Press the OK button to execute the command.
This completes the setup process for sampling.
5. Set the samples to be resampled in "Key" on the
"Recording– Audio Input" page.
Normally, this is set to the "Orig. Key" on the Recording
page.
Sampling and editing in SAMPLING mode Basic examples of sampling
6. Confirm that the "Auto +12dB On" checkbox is
7. On the IFX– Insert FX page, select "101: Reverb
8. Press the SAMPLING REC button and then the
Parameter settings using "Auto Resample
through IFX"
• Recording– Audio Input
selected on the Recording– Recording page.
Hall" for "IFX1", and set "IFX On/Off" to ON.
Press the key on the keyboard (C2) that is set in the
"Key" parameter to make sure that reverb is applied to
the resulting sound.
Also, make sure that the "Bus Sel." that comes after IFX1
in the output chain is set to "L/R".
SAMPLING START/STOP button.
The sample automatically assigned to C2 will be played,
and resampling will begin.
The sample will play back to the end, and resampling will
end.
The sample that was resampled in "Sample Select" will
automatically be assigned.
Note: To avoid the insert effect from being applied twice
when you monitor the result of a sound that was resam-
pled with an insert effect applied, "Bus Select" on the
IFX– Routing page will automatically be set to "L/R"
when resampling ends.
If you want to reapply the insert effect, change the setting
back to "IFX1".
– INPUT1 –
Bus Select: Off
Turn the input from the INPUT 1,2 and USB 1/2 jacks
off.
– Sampling Setup –
Source Bus: L/R
The sound sent to the L/R bus will be sampled.
Trigger: Sampling START Button
After you press the SAMPLING REC button and the
137

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nautilus-88Nautilus-73Nautilus-61Nautilus 88 at

Table of Contents