User Sample Bank Ids And Limitations - Korg NAUTILUS 61 AT Operation Manual

Table of Contents

Advertisement

Sampling (Open Sampling System)

User Sample Bank IDs and limitations

User Sample Bank IDs
Under the hood, the NAUTILUS keeps track of User Sample
Banks by a special ID saved in the KSC file. This lets the
system find and recognize the User Sample Bank if you
change the name or location on the drive, and even if it's
used on another NAUTILUS altogether.
An ID is initially assigned when the samples are created in
SAMPLING mode. This ID stays with the data as long as
you load and save using KSCs—even if you save to a
different location, or with a different name. It also stays with
the data regardless of whether it's loaded as a User Sample
Bank, or loaded into SAMPLING mode for editing.
It will not be preserved, however, if you load or save
individual Samples or Multisamples.
If there are multiple files on internal disks with the same ID,
the one with the most recent modification date one will be
used. KSCs on USB storage devices are ignored for this
purpose.
When you look at the bank name in Programs, Drum Kits,
and Wave Sequences, you'll see the full file path of the
associated KSC file.
What triggers a change to the User Sample Bank
ID?
SAMPLING mode is given a new ID under the following
circumstances:
• At system startup
• If the Clear Sampling Mode Data option is used when
loading a KSC which does not include Sampling Mode
Data
• When the Global Sample Management page's Unload
all in bank command is used for Sampling Mode Data
• When the GLOBAL > Basic Setup– KSC Auto Load
page's Do Auto-load Now command is used (unless one
of the auto-loaded files includes Sampling Mode Data, as
described below)
• On save, if Force new User Sample Bank ID is selected
(see "Force new User Sample Bank ID," below)
SAMPLING mode assumes the ID of an existing KSC under
the following circumstances:
• When a KSC with Sampling Mode Data is loaded using
the Clear Sampling Mode Data or Clear All options, or
when SAMPLING mode has not been used since startup
• Similar to the above, but when loading the entire folder
of Sampling Mode Data when browsing within a KSC
SAMPLING mode keeps its current ID under the following
circumstances:
• If SAMPLING mode has been used since startup, and a
KSC is loaded into SAMPLING mode with allocation set
to Append
• When individual Samples and/or Multisamples are
loaded
156
Force new User Sample Bank ID
This option is available in the Save Sampling Data dialog,
but not in the Save All dialog. It should be used only in
special cases.
For instance, you might use Force new User Sample Bank
ID if you have loaded a User Sample Bank, edited it
substantially, and wish to save the result as a totally new
User Sample Bank. After doing so, you'll also need to use
the Remap MS/Sample Banks menu command to assign
Programs, Wave Sequences, or Drum Kits to use the new
bank instead of the old one.
Limitations: Tone Adjust
Tone Adjust "MS Bank"
In the same way, the User Sample Bank is not
available as one of the banks that can be selected for
MS bank editing (meta-parameters) using the Tone
Adjust function. The selection is limited to ROM,
Sampling Mode Data, and EXs.
MS/WS/DKit Select can still be used to select different
Multisamples or Drumsamples from within the current bank,
including EXs above 125 and User Sample Banks, as long as
MS Bank is not used.
Tone Adjust

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nautilus-88Nautilus-73Nautilus-61Nautilus 88 at

Table of Contents