Technical Data; Input Data; Interfaces; Output Data - Fronius PVI1903OHM Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Technical data

Input data

Frequency
Nominal Voltage
Max. Input current

Interfaces

Modbus RTU
LAN
WLAN
Temperature sensor

Output data

Analogue out 1-phase / 3-phase
Nominal current analogue per phase
Short circuit current analogue out
Max. Current relay out
Multi-function relay out
Efficiency in rated operation
Consumption in standby

General data

Dimensions (height x width x depth)
Weight
Protection class
Installation
Ambient temperature range
Permissible humidity
Cooling
Storage temperature
EMC device class
Overvoltage category
Pollution degree
50 Hz
230 V / 400 V
1 X 16 A / 3 x 16 A
RS 485, max 1000 m, screened and twis-
ted
Ethernet min. CAT5, screened
IEEE 802.11 b/g/n
PT1000 (max. 30 m)
Continuously variable 0 - 3 / 0 - 9 kW
13 A
16 A (max. 5 sec.)
L2 / L3 16A (max. 5 sec.)
min. 15V / 2mA; max. 16 A (max. 5 sec.)
min. 98%
type 1.8 W
340 mm x 270 mm x 123 mm
3.9 kg
IP54
Wall
0 to 40 °C
0-99% (non-condensing)
Convection
-40 to 70 °C
B
3
3
119