06 Electrical Connection
Cable Requirements
Cable
DC input cable
PV cable that
(MC4)
meets 1100V
DC input cable
standard.
(Jinko)
Four-core/Five-
AC
core Copper/
output cable
Aluminum
cable
PE cable
Outdoors cable
Outdoor
shielded twisted
pair. The
Communication
cable
cable should
meet local
requirements.
Note:
[1]: When use Aluminum cable, please use a copper-aluminum transfer terminal.
[2]: The total length of the communication cable shall not exceed 1000m.
The values in this table are valid only if the external protective earth conductor is made of
the same metal as the phase conductor. Otherwise, the cross-sectional area of the external
protective earthing conductor shall be such that its conductivity is equivalent to that specified
in this table.
Type
Outer
Diameter
(mm)
6.1 - 8
5.5 - 8
18 - 30
[1]
-
4.5 - 7
[2]
User Manual V1.3-2024-01-25
Cable Specification
Cross-sectional Area (mm
Recommended: 4 - 6
Recommended: 4 - 6
For Brazil LV inverters,
Aluminum cable:
• GW12KLV-SDT-C30:
16 - 25
• GW17KLV-SDT-C30: 25
For other inverters,
Aluminum cable
• 8-15kW: 10 - 16
• 17-25kW: 16 - 25
• 27-30kW: 25
Aluminum wire
8 - 13
0.2 - 0.5
26
)
2
For Brazil LV inverters,
Copper cable:
GW12KLV-SDT-C30,
GW17KLV-SDT-C30:
16 - 25
For other inverters,
Copper cable
• 8-15kW: 6 - 10
• 17-30kW: 16 - 25
Copper wire
5 - 8