Installation Into An Adjacent Chimney - Valor 2700KN Installation Manual

Table of Contents

Advertisement

Venting

Installation Into an Adjacent Chimney

Required accessories:
• Co-axial to co-linear adapter at chimney face,
46DVA-34CLAA or equivalent;
• 2 lengths of 2-ply, fl exible chimney liner approved
for venting gas appliances:
• 1 x 3-inch diameter for air inlet and
• 1 x 4-inch diameter for exhaust;
• Co-linear termination kit 3 x 4 and fl ashing or
co-linear to co-axial adapter and either high wind
vertical vent terminal cap or a low profi le vertical
termination.
Restrictor must be set to Position 4 (see page 21).
This appliance must be completely framed and
maintain clearances to combustibles as shown
in this manual.
26
4" exhaust
liner
Co-linear
adapter
3" min. bend radius for
intake liner and 4" min.
bend radius for
exhaust liner
46DVA-34CLAA
(or 46DVA-GCL34)
Co-linear adapter.
Co-axial clearances
apply to adapter!
HeatShift
liners x4
(plenum not
pictured)
Framed
wall
(full height)
Clearances to
combustible
materials listed
elsewhere in this
manual apply
Co-Linear Conversion
Approved co-linear
termination or approved
co-linear adapter
and approved
co-axial
termination
3" intake
liner
Flashing
Engine
1 x 3"
intake liner
and
1 x 4"
exhaust
liner

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lt22700kp

Table of Contents