Venting; Overview - Valor 2700KN Installation Manual

Table of Contents

Advertisement

Venting

Top or Rear Outlet
This unit is supplied with a vent outlet which can
be installed either as top facing or rear racing. See
Appliance Preparation section for more information.
Vent Material
This unit is approved for installation using
4 x 6-5/8 inches co-axial direct vent pipe and
accessories as listed in the Approved Venting Components
section on pages 61–62 of this manual. Follow the
installation instructions supplied with the individual
venting accessories.
This unit may also be converted to co-linear (3" x 4")
venting for use in solid-fuel burning fi replaces and
chimneys using adapters and accessories—see list
in the Approved Venting Components section on pages
61–62 of this manual.
Vent Sealing
Seal all outer coaxial pipe and elbow joints, including
sectioned elbow joints, using high quality, high tem-
perature 2 inch wide self-adhesive aluminum foil tape
(Nashua-322-2 brand or similar). Wrap the tape com-
pletely around all joints and press fi rmly to seal.
A high temperature black silicone sealant may be used
in the outer joints as a substitute to foil tape.
Ensure all the pipe joints have a minimum of 1 ¼ inch
overlap.
Wall Thickness
The appliance vent is suitable for penetrating a
combustible wall assembly up to 8 inches in thickness.
A non-combustible wall can be of any thickness up to
the maximum horizontal run of vent pipe allowed for
the particular installation.
18
Tape all
OUTER joints
(including all
elbow joints)
Framing Vent in Combustible Walls & Ceilings
When penetrating through combustible walls and
ceilings, frame a minimum of 10 in x 10 in opening and
ensure that the insulation is kept clear of the vent pipe
using either a wall thimble or an attic insulation shield.
Follow the installation instructions supplied with the
individual venting components.
Align the vent center
to the center of the
frame
10" (254 mm)
Important Installer Notice – Weather
Sealing & Vapor Barriers
It is the installer's responsibility to ensure that vent
installations through exterior walls are caulked and
weatherproofed in such a manner as to:
• Prevent rain water from entering the wall from the
weather side by adequately caulking the outer vent
plate to the exterior wall surface.
• Prevent moisture inside the home from penetrat-
ing into the wall structure by ensuring the inside
wall plate is adequately sealed to the inside vapor
barrier.
• Prevent rain water and moisture from entering the
walls by sealing the joints between the outer vent
tube and the inner and outer wall plates.
We recommend the use of a high quality
polyurethane sealant.
All horizontal pipe runs must be graded 1/4 inch per
foot upwards in the direction of the exhaust fl ow. The
fi nal pipe length, when terminating through the wall
may be graded downwards slightly to prevent water
migration.