Installing the Ground Wire

5020-A2-GN10-60
To comply with Network Equipment Building System (NEBS) requirements, the
ground wire must be installed.
Procedure
1. Procure and ground a copper wire of appropriate diameter.
If you have a . . .
1-slot 5011 chassis
6-slot 5016 chassis
2. Strip back the insulation approximately 1/4 on the copper wire.
3. Locate the grounding lug on the chassis.
If you have a . . .
1-slot chassis
6-slot chassis
CO POTS Splitter
1-Slot Chassis
4. Loosen the screw on the
grounding lug.
5. Insert the stripped end of the wire
into the open end of the
grounding lug and tighten the lug's
screw. Make sure that the screw
is making contact with the
stripped portion of the wire.
Then the ground wire gauge must be . . .
10–14 AWG.
6–14 AWG.
Then the grounding lug is . . .
On the rear of the chassis on the left.
On the front of the chassis on the top right.
CO POTS Splitter
6-Slot Chassis
TM
April 2000
99-16338
98-15879-01