About the Hotwire POTS Splitter
5020-A2-GN10-60
The Hotwire system enables simultaneous high-speed digital data access and
analog voice service over the same twisted-pair telephone line. Simultaneous
access to RADSL (Rate Adaptive Digital Subscriber Line), M/SDSL (Multirate
Symmetric DSL), or MVL
Telephone Service) requires the installation of a POTS splitter at the central
office (CO). The CO POTS splitter separates the DSL and POTS frequencies.
Four CO POTS splitter models are available:
5020 RADSL 12-port Card
6020 MVL 12-port Card
6024 MVL 24-port Card
7020 M/SDSL 12-port Card
CO POTS
Splitter Card
DSL Interface
Loop Interface
PSTN Interface
The POTS splitter card is mounted in a POTS splitter chassis. Two chassis are
available:
Model 5011 – 1-slot card chassis which can be placed on a tabletop or
installed in a rack.
Model 5016 – 6-slot chassis which must be installed in a commercial
EIA-standard 19 or 23 rack or cabinet.
(Multiple Virtual Lines) service and POTS (Plain Old
April 2000
99-15428-01
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne Hotwire 5020

  • Page 1 Telephone Service) requires the installation of a POTS splitter at the central office (CO). The CO POTS splitter separates the DSL and POTS frequencies. Four CO POTS splitter models are available: 5020 RADSL 12-port Card 6020 MVL 12-port Card 6024 MVL 24-port Card...
  • Page 2: Product-Related Documents

    Be sure to register your warranty at www.paradyne.com/warranty. Document Title Hotwire 8600 DSLAM Installation Guide Hotwire 8610 DSLAM Installation Instructions Hotwire 8800 DSLAM Installation Guide Hotwire 8810 DSLAM Installation Instructions Hotwire 8820 GranDSLAM Installation Guide Technical Manuals April 2000 5020-A2-GN10-60...
  • Page 3 50-position connector. The following table shows the cables required in addition to those used to connect the POTS splitter to the local loop and the PSTN switch. POTS Splitter Compatible Card Port Cards 5020 RADSL 8510, 8540, and 12-port Card 8546 RADSL 4-port Card 6020 MVL 8310 MVL 4-port...
  • Page 4 A large #3 or #4 Phillips screwdriver to install the chassis into a rack. A flat-blade screwdriver to install the chassis grounding wire. Hotwire 5020, 6020, 6024, or 7020 POTS Splitter Card Package Checklist Verify that your POTS splitter card package contains the following:...
  • Page 5 — Six #10-32 x 1/4 Phillips flat-head mounting screws — Four #10-32 x 1/2 Phillips-head mounting screws — Four #12-24 x 1/2 Phillips-head mounting screws — Four #12-24 self-retaining nuts — Four black rubber feet CO POTS Splitter 1-Slot Chassis 5020-A2-GN10-60 Placement of Rubber Feet 99-15497-02 April 2000...
  • Page 6 — Six #10-32 x 1/4 Phillips flat-head mounting screws — Four #10-32 x 1/2 Phillips-head mounting screws — Four #12-24 x 1/2 Phillips-head mounting screws — Four #12-24 self-retaining nuts — Four black rubber feet (discard) CO POTS Splitter 6-Slot Chassis Filler Panels April 2000 99-15430-02 5020-A2-GN10-60...
  • Page 7 Center-mounting is recommended for convenient access to cables. Whether the rack has mounting rails with threaded or non-threaded screw holes. NOTE: Install chassis in the rack from the bottom up to maintain stability. 5020-A2-GN10-60 19" Cabinet POWER ALARMS Major Minor...
  • Page 8: Installing The Brackets

    Install the appropriate 19 or 23 brackets on the 1-slot or 6-slot chassis. 1-Slot Chassis 6-Slot Chassis Center Mount Front Mount Select one of the next two procedures for chassis installation in a rack. 19-Inch Rack 23-Inch Rack 99-15486-02 23-Inch Rack 19-Inch Rack 99-15434-02 April 2000 5020-A2-GN10-60...
  • Page 9 4. Loosely install the bottom screws first and then the top screws. 5. Tighten all screws firmly using a Phillips screwdriver. Repeat the process for each chassis. Chassis can be mounted directly on top of each other. 5020-A2-GN10-60 Front Rail Self-Retaining Screw...
  • Page 10 3. Loosely install the bottom screws first and then the top screws. 4. Tighten all screws firmly with a Phillips screwdriver. Repeat the process for each chassis. Chassis can be mounted directly on top of each other. Front Rail Screw 99-15435-01 April 2000 5020-A2-GN10-60...
  • Page 11: Installing The Ground Wire

    Make sure that the screw is making contact with the stripped portion of the wire. 5020-A2-GN10-60 Then the ground wire gauge must be . . . 10–14 AWG. 6–14 AWG. Then the grounding lug is . . .
  • Page 12 2. Slide the POTS splitter card into the chassis. 3. Tighten the 1/4-turn fastener on each side of the faceplate of the POTS splitter card. CO POTS Splitter 6-Slot Chassis 1/4-Turn Fastener DSL Interface Filler Panel Loop Interface PSTN Interface 1/4-Turn Fastener April 2000 99-15431-01 5020-A2-GN10-60...
  • Page 13 On the 8610 DSLAM, the DSL or MVL interface connectors are on the rear of the chassis. See Cables You Need on page 3 for information about POTS splitter and port card combinations you might use with an 8600 Series DSLAM. 5020-A2-GN10-60 Rear View of 8610 Chassis 3 Connectors...
  • Page 14 RIGHT UNIT: LINE B BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE SERIAL ALARM CLOCK SMCM Chassis 00-16708 5020-A2-GN10-60...
  • Page 15 Frame Connecting Block Rear View of 8820 GranDSLAM Chassis POWER ALARMS Major Minor 8 7 6 5 4 3 2 1 5020-A2-GN10-60 with 6024 POTS Splitter Main Distribution Frame Connecting Block POTS Splitter Rear View of 6-Slot 8820 GranDSLAM Chassis...
  • Page 16 Attach the short screw in the cable to the jack screw and tighten. Anchor Mount 50-Pin Connector Anchor Mount April 2000 Long Screw 97-15551 #4-40 Jack Screw Short Screw 97-15552 5020-A2-GN10-60...
  • Page 17 3. Tighten the tie wrap and trim the excess. Repeat the procedure for all the interface cables. CO POTS Splitter 6-Slot Chassis DSL Interface Loop Interface PSTN Interface 99-15432-01 5020-A2-GN10-60 April 2000...
  • Page 18 5. Position the cursor at the Start Transfer field. Use the spacebar to select Yes. Press Enter. 6. When the data transfer is complete, the Transfer Status field changes to Completed successfully. Status Identity Control Download Code April 2000 5020-A2-GN10-60...
  • Page 19: Connector Pin Numbers

    Pin assignments are the same for all three connectors on the central office POTS splitter cards. 50-Position Telco Connector* CO POTS Splitter # * 5020, 6020, and 7020 use first 12 pairs; 6024 uses 24 pairs. 5020-A2-GN10-60 Pin # Tip Pin # Ring...
  • Page 20 Telco connectors wired as shown in the following table. Y-Cable Wiring Wire Connector 1 Pin . . . Wire Connector 2 Connector 1 Pin . . . Pin . . . April 2000 Connector 3 Pin . . . 5020-A2-GN10-60...
  • Page 21 6-Slot 5016 Chassis Technical Specifications* Height x Width x Depth Weight Approvals Safety Certifications POTS Splitter Cards Technical Specifications* Height x Width x Depth Models 5020 & 6024 Model 6020 Model 7020 Weight Model 5020 Model 6020 Model 6024 Model 7020...
  • Page 22: Important Safety Instructions

    — Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. — Do not use the telephone to report a gas leak in the vicinity of the leak. April 2000 5020-A2-GN10-60...
  • Page 23: Warranty, Sales, Service, And Training Information

    Hotwire is a registered trademark of Paradyne Corporation. MVL is a trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners. Copyright 2000 Paradyne Corporation 5020-A2-GN10-60 April 2000...