Paradyne Hotwire 6020 Installation Instructions Manual

Mvl pots splitter central office
Hide thumbs Also See for Hotwire 6020:

Advertisement

Quick Links

Hotwire
6020 MVL
Installation Instructions
Document Number 6020-A2-GZ40-00
March 1998
About the Hotwire

Before You Begin

Cables and Hardware You Need
6020-A2-GZ40-00
TM
POTS Splitter Central Office
MVL
POTS Splitter
The Hotwire MVL (Multiple Virtual Lines) System enables simultaneous
high-speed digital data access and analog voice service over the same
twisted-pair telephone line. The simultaneous access to MVL and POTS (Plain
Old Telephone Service) requires the installation of a POTS splitter at the central
office (CO). A CO POTS splitter is not necessary when the MVL line is not used
with analog voice for POTS.
The POTS splitter filters out the MVL signal and allows the POTS frequencies to
pass through. Each central office POTS splitter card contains 12 filters to serve
12 local loops with MVL-based service and POTS. The POTS splitter card is a
passive device and requires no power. The POTS splitter chassis is shipped
separately from the POTS splitter card(s). Two chassis are available:
1-slot chassis which can be placed on a tabletop or installed in a rack.
6-slot chassis which must be installed in a commercial EIA-standard
19 or 23 rack or cabinet.
Consider the following before installing the POTS splitter:
Installation Site
The location should be well-ventilated, clean, and free of environmental
extremes. Allow clearance at the front of the POTS splitter chassis to provide
access to the cables.
Cabling
Three Telco 50-conductor cables are used to connect to the three interfaces
on the POTS splitter card. The location of the system hardware affects the
length of the three cables.
For each POTS splitter card, obtain three Telco 50-conductor cables with
50-position amphenol-type connectors at the appropriate length based on cabling
requirements in your environment.
Refer to
Cabling Overview ,
March 1998
page 11, and
Connector Pin
Numbers, page 17.
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne Hotwire 6020

  • Page 1: Before You Begin

    Hotwire 6020 MVL Installation Instructions Document Number 6020-A2-GZ40-00 March 1998 About the Hotwire The Hotwire MVL (Multiple Virtual Lines) System enables simultaneous high-speed digital data access and analog voice service over the same twisted-pair telephone line. The simultaneous access to MVL and POTS (Plain Old Telephone Service) requires the installation of a POTS splitter at the central office (CO).
  • Page 2 — Four #10-32 x 1/2 Phillips-head mounting screws — Four #12-24 x 1/2 Phillips-head mounting screws — Four #12-24 speed nuts — Four black rubber feet Warranty card CO POTS Splitter 1-Slot Chassis Placement of Rubber Feet 98-15497-01 March 1998 6020-A2-GZ40-00...
  • Page 3: Tools Required

    A small #1 or #2 Phillips screwdriver to tighten the POTS splitter card fasteners. A large #3 or #4 Phillips screwdriver to install the chassis into a rack. A flat-blade screwdriver to install the ground wire. 6020-A2-GZ40-00 Filler Panels March 1998...
  • Page 4: Product-Related Documents

    Installation Instructions Hotwire 6310 MVL Modem Customer Premises Installation Instructions Hotwire 8310 MVL Card Installation Instructions Hotwire 8600 Digital Subscriber Line Access Multiplexer (DSLAM) Installation Guide Hotwire 8800 Digital Subscriber Line Access Multiplexer (DSLAM) Installation Guide Technical Manuals March 1998 6020-A2-GZ40-00...
  • Page 5 If a 1-slot chassis is being placed on a tabletop. If so, plan to install the rubber feet chassis. NOTE: In order to reduce the risk of accidental tip over, it is strongly recommended that the chassis be installed into the rack from the bottom up. 6020-A2-GZ40-00 19" Cabinet POWER ALARMS Major Minor POTS...
  • Page 6: Installing The Brackets

    Install the appropriate 19 or 23 brackets on the 1-slot or 6-slot chassis. 1-Slot Chassis 6-Slot Chassis Center Mount Front Mount Select one of the next two procedures for chassis installation in a rack. 19-Inch Rack 23-Inch Rack 98-15486-01 23-Inch Rack 19-Inch Rack 98-15434-01 March 1998 6020-A2-GZ40-00...
  • Page 7 After installing the appropriate brackets on the chassis: 1. Determine the preferred placement of the chassis in the rack. 2. Insert a speed nut onto each mounting rail hole selected and align the hole of the speed nut with the hole in the rail. 6020-A2-GZ40-00 March 1998...
  • Page 8: Installing The Ground Wire

    1-slot chassis 6-slot chassis CO POTS Splitter 1-Slot Chassis Then the ground lug is . . . On the rear of the chassis on the left. On the front of the chassis on the top right. 98-15876 March 1998 6020-A2-GZ40-00...
  • Page 9 4. Insert the stripped end of the wire into the open end of the GND lug and tighten the lug’s screw. Make sure that the wire is making contact with the stripped portion of the wire. 6020-A2-GZ40-00 Then the ground wire gauge must be . . . 10 — 14 AWG 6 —...
  • Page 10 1. Insert the POTS splitter card into the chassis. 2. Tighten the two 1/4-turn fasteners in the faceplate for each installed POTS splitter card. DSLAM Interface CO POTS Splitter 1-Slot Chassis 1/4-Turn Fastener Loop Interface PSTN Interface March 1998 1/4-Turn 98-15850 Fastener 6020-A2-GZ40-00...
  • Page 11: Cabling Overview

    The 12 pairs can be connected directly to the DSLAM using a straight-through cable or connected directly to the MDF. In order to directly connect 24 pairs, use a Y-cable to combine 12 pairs from two POTS splitter cards. 6020-A2-GZ40-00 CO POTS Splitter 6-Slot Chassis...
  • Page 12: Cabling Examples

    PSTN Interface connects to the local PSTN switch. In the next example, the first two POTS splitter cards are combined using a Y-cable. Main Distribution Frame Cross-Connect Block Y-Cable POTS Splitter 6-Slot Chassis PSTN POWER ALARMS Switch Major Minor 8800 DSLAM Chassis 98-15804-01 March 1998 6020-A2-GZ40-00...
  • Page 13 Cross-Connect Connector Pin Numbers Refer to Y-Cable Installation A Y-cable is available to combine two POTS splitter cards with 12 pairs to one DSLAM card with 24 pairs. The Y-cable part number is 8000-F1-001. 6020-A2-GZ40-00 Frame Block Block POWER ALARMS...
  • Page 14 P2 To 1-12 P3 To 13-24 LINES March 1998 To P1 Connector Pairs 1 to 12 Captive Screw To P1 Connector Pairs 13 to 24 Captive Screw 98-15806-01 POTS Splitter 6-Slot Chassis 8800 DSLAM POWER ALARMS Major Minor Chassis 98-15805-01 6020-A2-GZ40-00...
  • Page 15 2. Feed the cable head through the chassis’ front right or left opening. 3. Install the plastic tie-wrap anchor onto the faceplate on the cable exit side with the screws provided. 4. Slide the tie wrap through the anchor from the top. 6020-A2-GZ40-00 CO POTS Splitter Card Loop Interface PSTN Interface To connect to the .
  • Page 16 Attach the short screw in the cable to the jack screw and tighten. 6. Tighten the tie wrap and trim the excess. Repeat the procedure for all the interface cables. March 1998 6020-A2-GZ40-00...
  • Page 17: Connector Pin Numbers

    DSLAM Interface Connector Pin Numbers Pin assignments are the same for all three connectors on the CO POTS splitter card. Pin 25 Pin 50 6020-A2-GZ40-00 CO POTS Splitter 6-Slot Chassis Loop Interface PSTN Interface 50-Position Amphenol-type Connector Filter # Pin 1...
  • Page 18: Technical Specifications

    Technical Specifications POTS Splitter 6020 Card Technical Specifications Item Height x Width x Depth Weight Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration POTS Splitter 5011 (1-Slot) Chassis Technical Specifications* Item Height x Width x Depth Weight...
  • Page 19: Important Safety Instructions

    Via the Internet: Visit the Paradyne World Wide Web site at http://www.paradyne.com Via Telephone: Call our automated call system to receive current information via fax or to speak with a company representative. — Within the U.S.A., call 1-800-870-2221 — Outside the U.S.A., call 1-727-530-2340 6020-A2-GZ40-00 March 1998...
  • Page 20: Patent Notification

    Patent Notification Hotwire MVL products are protected by U.S. Patents: 4,637,035, 4,744,092, 4,669,090, 5,291,521 and 5,280,503. Other U.S. and foreign patents pending. Copyright 1998 Paradyne Corporation *6020–A2–GZ40–00* March 1998 6020-A2-GZ40-00...

Table of Contents