Installing The Ground Wire - Paradyne BitStorm 6051 Installation Instructions Manual

Pots splitter
Hide thumbs Also See for BitStorm 6051:
Table of Contents

Advertisement

Installing the Ground Wire

To comply with Network Equipment Building System (NEBS) requirements, the
ground wire must be installed.
Procedure
10
1. Obtain copper wire of appropriate wire gauge:
If you have a . . .
1-slot 5011 chassis
6-slot 5016 chassis
2. Strip back the insulation approximately 6 mm (1/4 ) on the copper wire.
3. Locate the grounding lug on the chassis:
If you have a . . .
1-slot chassis
6-slot chassis
POTS Splitter
1-Slot Chassis
4. Loosen the screw on the
grounding lug.
5. Insert the stripped end of the
wire into the open end of the
grounding lug and tighten the
lug's screw. Make sure that
the screw is making contact
with the stripped portion of
the wire.
April 2002
Then the ground wire gauge must be . . .
10–14 AWG.
6–14 AWG.
Then the grounding lug is . . .
On the rear of the chassis on the left.
On the front of the chassis on the top right.
POTS Splitter
6-Slot Chassis
TM
02-17155
98-15879-01
6051-A2-GZ40-00

Advertisement