Installing the Ground Wire
To comply with Network Equipment Building System (NEBS) requirements, the
ground wire must be installed.
Procedure
10
1. Obtain copper wire of appropriate wire gauge: 14–10 AWG (2.08–5.26 mm
2. Strip back the insulation approximately 1/4 (6 mm) on the copper wire.
3. Locate the grounding lug on the chassis:
If you have a . . .
1-slot chassis
6-slot chassis
POTS Splitter
1-Slot Chassis
4. Loosen the screw on the
grounding lug.
5. Insert the stripped end of the
wire into the open end of the
grounding lug and tighten the
lug's screw. Make sure that
the screw is making contact
with the stripped portion of
the wire.
July 2002
Then the grounding lug is . . .
On the rear of the chassis on the left.
On the front of the chassis on the top right.
POTS Splitter
6-Slot Chassis
TM
2
).
02-17155
98-15879-01
6051-A2-GZ40-10