Paradyne Hotwire 6050 Installation Instructions Manual

Central office universal pots splitter

Advertisement

Quick Links

®
Hotwire
Central Office Universal POTS Splitter
Models 6050 and 7020

Installation Instructions

Document Number 6050-A2-GZ40-20
August 2001
About the Hotwire POTS Splitter
The Hotwire
analog voice service over the same twisted-pair telephone line. The CO (central
office) POTS (plain old telephone service) splitter separates the DSL (Digital
Subscriber Line) and POTS frequencies.
Simultaneous access to POTS and data requires the installation of a POTS splitter
at the CO for:
T
T
T
T
T
POTS Splitter Chassis
The Hotwire POTS splitter card is mounted in a Hotwire POTS Splitter Chassis.
Two chassis models are available:
T
T
6050-A2-GZ40-20
®
system enables simultaneous high-speed digital data access and
ADSL/G.Lite (Adaptive DSL)
RADSL (Rate Adaptive DSL)
ReachDSL
®
MVL
(Multiple Virtual Lines)
TDM SDSL (Time Division Multiplexer Symmetric DSL)
Chassis Model 5011 – 1-slot chassis which can be placed on a tabletop or
installed in a rack.
Chassis Model 5016 – 6-slot chassis which must be installed in a commercial
EIA-standard 19 or 23 rack or cabinet.
August 2001
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne Hotwire 6050

  • Page 1: Installation Instructions

    ® Hotwire Central Office Universal POTS Splitter Models 6050 and 7020 Installation Instructions Document Number 6050-A2-GZ40-20 August 2001 About the Hotwire POTS Splitter The Hotwire analog voice service over the same twisted-pair telephone line. The CO (central office) POTS (plain old telephone service) splitter separates the DSL (Digital Subscriber Line) and POTS frequencies.
  • Page 2 7020 TDM SDSL 12-port POTS Splitter Card (not available for use in North America) DSL Interface NOTES: — The Hotwire 6050 Universal POTS Splitter Card is compatible with: ADSL: Any product compliant with standard T1.413 Issue 2 and/or G.992.1 Type 2 RADSL: All Hotwire RADSL line cards providing POTS ReachDSL/MVL: All Hotwire ReachDSL/MVL line cards providing POTS —...
  • Page 3: Product-Related Documents

    PSTN switch Securing the cables Verifying the firmware level of the port cards (TDM SDSL only) Be sure to register your warranty at www.paradyne.com/warranty. 6050-A2-GZ40-20 Document Title Hotwire 8610 DSLAM Installation Guide Hotwire 8620 GranDSLAM Installation Guide...
  • Page 4 Each DSL port at the DSLAM uses one pair of copper wires out of the 25 pairs on each 50-position connector. The following tables show the cables that can be used to connect 6050 and 7020 POTS splitter cards to the DSL interface at the DSLAM. Table 1. 6050 24-Port DSL POTS Splitter Card...
  • Page 5 A large #3 or #4 Phillips screwdriver to install the chassis into a rack. A flat-blade screwdriver to install the chassis grounding wire. Hotwire 6050 or 7020 POTS Splitter Card Package Checklist Verify that your POTS splitter card package contains the following:...
  • Page 6 CO POTS Splitter 1-Slot Chassis NOTE: If your 1-slot 5011 POTS splitter chassis is being placed on a tabletop, install the rubber feet as shown above. Discard the rubber feet for a rack-mounted chassis. Placement of Rubber Feet 99-15497-02 August 2001 6050-A2-GZ40-20...
  • Page 7 — Six #10-32 x 1/4 Phillips flat-head mounting screws — Four #10-32 x 1/2 Phillips-head mounting screws — Four #12-24 x 1/2 Phillips-head mounting screws — Four #12-24 self-retaining nuts — Four black rubber feet (discard) CO POTS Splitter 6-Slot Chassis 6050-A2-GZ40-20 Filler Panels August 2001 99-15430-02...
  • Page 8 Whether the rack has mounting rails with threaded or non-threaded screw holes. NOTE: Install chassis in the rack from the bottom up to maintain stability. 19" Cabinet POWER ALARMS Major Minor POTS Splitter 6-Slot Chassis POWER ALARMS Major Minor August 2001 19" Rack 00-15426b 6050-A2-GZ40-20...
  • Page 9: Installing The Brackets

    Install the appropriate 19 or 23 brackets on the 1-slot or 6-slot chassis. 1-Slot Chassis 6-Slot Chassis Center Mount Front Mount Select one of the next two procedures for chassis installation in a rack. 6050-A2-GZ40-20 19-Inch Rack 23-Inch Rack 99-15486-02 23-Inch Rack 19-Inch Rack...
  • Page 10 4. Loosely install the bottom screws first and then the top screws. 5. Tighten all screws firmly using a Phillips screwdriver. Repeat the process for each POTS splitter chassis. POTS splitter chassis can be mounted directly on top of each other. Front Rail Self-Retaining Screw August 2001 00-15436-02 6050-A2-GZ40-20...
  • Page 11 3. Loosely install the bottom screws first and then the top screws. 4. Tighten all screws firmly with a Phillips screwdriver. Repeat the process for each POTS splitter chassis. POTS splitter chassis can be mounted directly on top of each other. 6050-A2-GZ40-20 Front Rail Screw 99-15435-01...
  • Page 12: Installing The Ground Wire

    10–14 AWG. 6–14 AWG. Then the grounding lug is . . . On the rear of the chassis on the left. On the front of the chassis on the top right. CO POTS Splitter 6-Slot Chassis August 2001 99-16338 98-15879-01 6050-A2-GZ40-20...
  • Page 13 2. Slide the POTS splitter card into the chassis. 3. Tighten the 1/4-turn fastener on each side of the faceplate of the POTS splitter card. CO POTS Splitter 6-Slot Chassis 1/4-Turn Fastener DSL Interface 6050-A2-GZ40-20 Filler Panel Loop Interface PSTN Interface 1/4-Turn Fastener August 2001...
  • Page 14 Cabling with an 8610 DSLAM or 8620 GranDSLAM The DSL interface connectors are on the rear of the 8610 DSLAM and 8620 GranDSLAM chassis. This example shows the one-slot 24-port 6050 POTS splitter card with two 12-port DSL cards connected via a Y-cable to the 8610 DSLAM.
  • Page 15 7020 12-Port POTS Splitters Cards and Hotwire 8810 DSLAM Main Distribution Frame Connecting Block POWER ALARMS Major Minor 6050-A2-GZ40-20 TDM SDSL 4-Port Cards with 7020 12-Port POTS Splitter Cards and Hotwire 8820 GranDSLAM Main Distribution Frame Connecting Block Connecting...
  • Page 16 Cabling to 12-Port DSL Cards To connect one 6050 24-port POTS splitter card to two DSL 12-port cards in the 8810 DSLAM or 8820 GranDSLAM, use a Y-cable at the rear of the DSLAM, as shown in the next example.
  • Page 17 — If the connector on the cable has a short screw, install the #4-40 jack screw provided into the threaded hole of the connector in the circuit card. Attach the short screw in the cable to the jack screw and tighten. Anchor Mount 6050-A2-GZ40-20 POTS Splitter Card Faceplate Long Screw...
  • Page 18 3. Tighten the tie wrap and trim the excess. POTS Splitter Card Faceplate 00-15553-01 Repeat the procedure for all the interface cables. CO POTS Splitter 6-Slot Chassis DSL Interface Loop Interface PSTN Interface 99-15432-01 August 2001 6050-A2-GZ40-20...
  • Page 19 5. Position the cursor at the Start Transfer field. Use the spacebar to select Yes. Press Enter. 6. When the data transfer is complete, the Transfer Status field changes to: Completed successfully. For additional information, refer to the TDM SDSL Port Card user’s guide. 6050-A2-GZ40-20 Status Identity Control Download Code...
  • Page 20: Connector Pin Numbers

    Pin assignments are the same for all three connectors on the central office POTS splitter cards. 50-Position Telco Connector* CO POTS Splitter # * 6050 uses 24 pairs; 7020 uses the first 12 pairs Pin # Ring Pin # Tip August 2001...
  • Page 21 Y-Cable Wiring The Y-cable referred to in Telco connectors wired as shown in the following table. The Y-cable part number is 8000-F1-001. Captive Screw 6050-A2-GZ40-20 Cables You Need on page 4 must have three 50-pin Y-Cable Pairs 1-12 Captive Screw...
  • Page 22: Technical Specifications

    6-Slot 5016 Chassis Technical Specifications* Height x Width x Depth Weight (empty) Approvals Safety Certifications POTS Splitter Cards Technical Specifications* Height x Width x Depth Models 6050 & 7020 Weight Model 6050 Model 7020 Compliance – 6050 Physical Environment Operating temperature...
  • Page 23: Important Safety Instructions

    European Directives: Directive 72/72/33C – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68EEC. 6050-A2-GZ40-20 August 2001...
  • Page 24: Warranty, Sales, Service, And Training Information

    Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners. Copyright © 2001 Paradyne Corporation. Printed in U.S.A.    .   *6050-A2-GZ40-20 August 2001 6050-A2-GZ40-20...

This manual is also suitable for:

Hotwire 7020

Table of Contents