Paradyne COMSPHERE 6800 Series Command Reference Manual page 45

Network management system, communications products support
Table of Contents

Advertisement

COMSPHERE 6800 Series Network Management System
Action upon exceeding maximum number (Required field)
SHORT HOLDING TIME FAULT CRITERIA
Entries into data mode/sample (Required field)
Minimum average call holding time/sample (Required field)
Action upon exceeding minimum average (Required field)
2-22
Enter one of the following options:
report-fault
The no answer fault is immediately reported to the NMS when the specified
maximum number of non-answered calls is reached.
make-busy-and-report-fault
The no answer fault is immediately reported to the NMS and the modem is
placed in the busy state.
no-action
The no answer fault is not reported. Use this option to keep a running total of
the traffic statistics counters without having alerts reported when the specified
number is reached. Statistics can be examined using the Call Fault Read (cfr)
command. The counters are the number of answered calls, non-answered calls,
and calls that enter the data mode.
skip
When a no answer or short holding time fault parameter is reset with the cfc
command, all the traffic statistics counters are reset to zero; however, if skip is
entered here, the counters for the no answer fault are not reset to zero.
Enter the number of calls entering the Data mode in the sample. Valid entries are from 5
through 100.
Enter the minimum average Data mode holding time (in seconds). Valid values are from 1
to 600 seconds.
Enter one of the following:
report-fault
The short holding time fault is reported to the NMS whenever a call does not
achieve the specified minimum holding time.
January 1997