9.0 INSTALLATION

9.1 Tyre-Changer site requirements

When choosing the place of installation be sure that it
complies with current safety-at-work regulations.
The Tyre-Changer must be connected to the main
electric power supply and the compressed air system. It
is therefore advisable to install the machine near these
power sources.
The installation area must leave at least the room shown
in picture "fig. 1", so as to allow all parts of the machine
to operate correctly and without any restriction.

9.2 Tyre-Changer placement and connections

Place Tyre-Changer onto a flat, smooth and not slippery floor with a suitable load capacity.
The machine need not necessarily be anchored to the ground, but if you prefer to
do so, drill 2 deep holes (100 mm) on the ground in correspondance of 2 holes of
the machine rear base by using a 10 mm drill bit of suitable length. Insert the two
brackets A and B (Fig. 2) into the machine base from the front, and drill two holes
the same as previous ones.
Insert suitable metal anchor dowels in the holes drilled and secure firmly.
If the machine is installed outside it must be protected by a appropriate lean-to shed.
The installation site should be equipped with an electrical system with an adequate
grounding circuit equipped with an appropriate ground fault circuit – breaker set for
16 A placed in a visible and accessible place by the operator and equipped with
power indicator light.
NOTE: If the machine is supplied without the electrical plug, the user shall fit one -at least 16A- that is suitable for the
voltage of the machine and complies with current regulations.
Before connecting the machine, please check that the characteristics of your networks
correspond to those indicated by machine's data-label.
Even small jobs done on the electrical system must be carried out by professionally qualified
personnel.
The Manufacturer is not responsible for damages caused by electrical connection different
from the original indications.
Unplug the unit from electrical and pneumatic outlets before moving and servicing.
The pneumatic network of the installation area must be provided with min. 8 bar working
pressure outlet.
- Connect the machine to the compressed air network by means of
located at the rear side of the machine.
700mm
700
the air connection unit
9
1690mm
1760
A
Fig. 1
700mm
200
Fig. 2
B