11 March 2022 WARNING .This document contains information which is the property of FASEP 2000 rl and all rights are reserved. This manual shall not be photocopied or reproduced in any way without the prior written consent of FASEP 2000 srl.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 PRESENTATION Intended Use This unit is designed to measure and correct static and dynamic unbalance of vehicle wheel, the dimension and weight of which are within the working range of the machine (see “Technical Data”appendix for reference) This unit is meant for a professional use.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 INSTALLATION Moving the unit WARNING When the unit has to be moved: never lift balancer by motor shaft or by neighborhood of it. Assembling the unit For ease of transportation, the wheel balancer might be disassembled into units. If necessary, assembling instruction are provided within each package..
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 USE OF CONTROL PANEL Fig. 6 Panel V555 Meaning of the icons on the screen Select balancing mode Delete last character in input activation code Fig. 7 Fig. 10...
Page 8
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 Diagnostic Laser calibration Fig. 13 Fig. 20 Key down Put in the rod laser in rest position Fig. 14 Fig. 21 Position calibration Start laser Fig. 15 Fig. 22...
Page 9
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 Key SET/OK Set measures Fig. 27 Fig. 34 Double operator Go to setup menù Fig. 28 Fig. 35 Optimize Skip current operation Fig. 29 Fig. 36 Restart software Split function Fig.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 CALIBRATION OF WHEEL BALANCER (USER) How to calibrate the wheel balancer (USER) NOTE: the following symptoms indicate need for calibration:: a) check calibration program fails. b) constant low or high weight readings.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 How to control the calibration of wheel balancer and position weight (USER) Switch on the wheel balancer. Select SET UP > CALIBRATION > SET/OK > CHECK CALIBRATION > SET/OK.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 Calibration ALU-SE Switch on the wheel balancer. MAIN MENU > MENU > RESET > CALIB > ALU-SE CALIBRATION > SET/OK (fig..49). Put the rod on rest position (fig.49) and press SET/ OK.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 Calibration SONAR NOTE Sonar calibration is only available for qualified personnel.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 MEASUREMENT AND CORRECTION OF UNBALANCE Placing the wheel rim on the wheel balancer 7.1.1 Select the cone or flange suitable for the wheel to be balanced. Specific mounting instructions are delivered with each flange ...
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 Input of Rim Dimensions (ALU-SE) MAIN MENU > INPUT > ALU MODE Press ALU MODE untill the required position of weight is on the video (fig.56). Insert the distance (IN1).
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 How to apply the weight using ALU-SE applicator Place the weight as in the picture 61. Turn the wheel until reach the application position of the weight (fig. 60).
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 SPECIAL FUNCTIONS Language selection 8.1.1 MAIN MENU >SET UP > USER SET UP > LANGUAGE > SET OK >. 8.1.2 Select the language and press SET OK. Setup 8.2.1...
[when servicing the unit] Make sure power sources are disconnected before service on the unit is performed. Service to PCB, electrical and mechanical parts should be done only by an Authorized FASEP 2000 Service Center. Identifying warning signals Unreadable and missing warning labels must be replaced immediately.
Fasep 2000 srl Rev. 1.8 Videotronic V548.G4.U: User’s Manual 11 March 2022 Errors and Malfunctions recognized by the Computer Errors may apply to some model only. ERR 1: Shaft does not rotate ERR 2: Rotation Direction is wrong ERR 3: Rotation speed is not ready...
Page 22
BS EN 60204-1:2018 BS EN IEC 61000-6-3:2021 BS EN IEC 61000-6-1:2019, BS ISO/IEC 17050-1:2010 Ronta, Firenze Data_____________ FASEP 2000 srl Fulvio Boni,Presidente Persona autorizzata a costituire il Fascicolo Tecnico: Fasep 2000 srl, Via Faentina 96 - Ronta, 50032 Borgo San Lorenzo (Fi)
Page 23
UNI EN ISO 12100:2010, EN 60204-1:2018, BS EN IEC 61000-6-3:2021, BS EN IEC 61000-6-1:2019, ISO/IEC 17050-1:2010 Ronta, Firenze Data_____________ FASEP 2000 srl Fulvio Boni,Presidente Persona autorizzata a costituire il Fascicolo Tecnico: Podmiot odpowiedzialny za dostarczenie dokumentacji techniczenej: Fasep 2000 srl, Via Faentina 96 - Ronta, 50032 Borgo San Lorenzo (Fi)
Need help?
Do you have a question about the V548.G4.U and is the answer not in the manual?
Questions and answers