Working Environment Condi; Tions; Working Position; Installation Space - Fasep RGU600E Instruction Manual

Table of Contents

Advertisement

7522-M001-14_P
GB
Page 17 of 168
GG40256.11SL - GG40256.11ST - GG40256.15
GG40256T.15 - GG40256A.15 - GG40256D.15
GG40256TD.15 - GG40256.15SL - GG60360.15
GG60360T.15 - GG60360A.15 - GG60360D.15 - GG60360TD.15
8.0

WORKING ENVIRONMENT CONDI-

TIONS

The machine must be operated under proper condi-
tions as follows:
• temperature: 0° + 55° C
• relative humidity 30 - 95% (dew-free)
• atmospheric pressure: 860 - 1060 hPa (mbar).
The use of the machine in ambient conditions other
than those specified above is only allowed after prior
agreement with and approval of the manufacturer.
8.1

Working position

In Fig. 12 it's possible to define working positions A,
B, C, D which will be referred to in the description of
machine operative phases.
Positions A and B must be considered as main posi-
tions for tyre mounting and demounting and for wheel
clamping on the mandrel, while positions C and D are
the best positions to follow tyre bead breaking and
demounting operations.
Working in these positions allows better precision and
speed during operating phases as well as greater safety
for the operator.
8.2

Installation space

Fig. 12
C
B
A
INSTALL THE MACHINE INDOORS OR IN A RO-
OFED AREA. PLACE OF INSTALLATION MUST
BE DRY, ADEQUATELY LIT AND IN COMPLIAN-
CE WITH APPLICABLE SAFETY REGULATIONS.
The location of the machine requires a usable space of
5800x4500 mm, (as indicated in Fig. 12). The positio-
ning of the machine must be according to the distances
shown. From the control position the operator is able
to observe all the machine and surrounding area. He
must prevent unauthorized personnel or objects that
could be dangerous from entering the area.
The machine must be fixed on a flat floor surface, pre-
INSTRUCTION, USE
AND MAINTENANCE MANUAL
ferably of cement or tiled. Avoid yielding or irregular
surfaces.
The base floor must be able to support the loads
transmitted during operation. This surface must have
a capacity load of at least 500 kg/m².
The depth of the solid floor must be sufficient to gua-
rantee that the anchoring bolts hold.
8.3
The machine does not require its own lighting for nor-
mal working operations. However, it must be placed
in an adequately lit environment.
For correct lighting, use lamps having total power
800/1200 Watt as envisaged by UNI 10380.
9.0
9.1
The packed machine is fixed to the pallet through the
holes prearranged on the frame. Such holes also fix the
machine to the ground through anchor small blocks
as shown in Fig. 13.
D
• Execute four holes with 12 mm diameter on the floor
• introduce the small blocks in the holes;
• fix the machine to the ground with four M12x120

Lighting

MACHINE ASSEMBLY

Anchoring system

Fig. 13
GG40256.15
GG40256T.15
GG40256.11SL
GG40256A.15
GG40256.11ST
GG40256D.15
GG40256TD.15
GG40256.15SL
a = 1185 mm
a = 1185 mm
b = 1840 mm
b = 2173 mm
by the holes on the bottom floor;
mm screws (or four 12x80 mm stud bolts). Tighten
the screws with an approximate tightening torque
of 70 Nm.
GG60360.15
GG60360T.15
GG60360A.15
GG60360D.15
GG60360TD.15
a = 1216 mm
b = 2265 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gg60360

Table of Contents