Syncing Tool To Controller - Band-it IT7000 User Manual

Table of Contents

Advertisement

User Manual

SYNCING TOOL TO CONTROLLER

How to connect or replace an existing tool to the controller:
1.
Activate E-stop or turn controller off to disable air and power to motor.
2.
Disconnect data and motor cable to current tool (only required if a tool is connected).
3.
Disconnect pneumatic tubing harness to current tool (if required)
4.
Connect data and motor cable to new tool.
5.
Connect pneumatic tubing harness to new tool
Release E-stop or turn controller back on. Ensure Door Latch is in the On position.
6.
7.
Tool Setup automatically appears (skip step 1), if not go to settings screen (General tab)
1. Select "New Tool / Maintenance"
2. Select the Enter Serial Number field
3. Type in the new tool's serial number
4. Select "Enter"
5. Enter "Tool Cycle Count"
6. Select Maintenance Items that have been performed
7. Select "Done" then "Yes" to confirm selections
Input tool settings (If changing application)
8.
1.
2.
3.
Message banner at top of screen should read
9.
If an
error
Note: When powering on the controller, it takes approximately 30 seconds for the system to
be functional. Air pressure and motor power will not be activated until after this point.
Power Switch
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Set system pressure and punch pressure (Refer to settings, page 32)
Set target torque (Refer to settings, page 32)
Set ejection preference
is shown, press the error reset button.
E-Stop
Door Latch
.
"Tool
Ready" and the tool is ready to use.