Guarding And Interlocks - Band-it IT7000 User Manual

Table of Contents

Advertisement

User Manual

GUARDING AND INTERLOCKS

Safeguards:
Main Tool Housing: Covers primary mechanical body and actuators to prevent pinching during
operation. Do not attempt to access an open gaps during tool operation.
Head cover: Covers the mechanical head piece of the tool to prevent pinching during cutoff process. Do
not place fingers in head area or under band during operation.
Circuit breaker: Housed inside main enclosure.
Power cord: Main method of removing power to unit. Unplug from wall or main enclosure.
Interlocking functions and features:
Securing machine for safe maintenance:
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
The tool is not intended to operate without guards in place. The tool does not have any interlock
functions or features that prevent operation if the guards are missing or enclosures are open. It
is the responsibility of the user to provide safety interlocks if required.
The tool must have all power and compressed air sources removed before service.
All guards must be replaced, and enclosures closed before power and air sources are
reconnected to the unit.
Before preventive maintenance, disconnect device from wall. The appliance plug is the
disconnect device.
The Device comes with an emergency stop (E-Stop button) that cuts power to the motor and air
to the pneumatics bank when depressed (activated)
Figure 1
6
IT8000 3/8" TIE-LOK DATA TOOL
IT7000 1/4" TIE-LOK DATA TOOL
ITC800 CONTROL SYSTEM
E-Stop
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itc800It8000

Table of Contents