AIR FLOW TIMING

The following chart shows the cylinder actuation for one complete tie install.
Event description
Timing / duration
Clamp cylinder
Extend
Extend
Punch cylinder
Retract
Trigger cylinder
Extend
Extend
Cut-off cylinder
Retract
Pressurize
Exhaust
*Scrap Ejection: If the automatic ejection setting is ON (recommended), the tail scrap will be automatically
released from the tension wheels after the cut operation to ease in pulling out scrap. Otherwise, the tool will
wait for the next trigger press to eject scrap. Note: Regardless of the setting, the scrap will have to be pulled out
by hand. See HMI settings to change the setting (pg. 37)
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Tool ready
Engage
for next tie
gripper
Entire
duration of
tensioning
duration of
At rest
tie and
tightening
ejecting
scrap
Tension
clamp /
Actuate
Retract
engage
trigger to
punch
punch
dimple
cylinder
Entire
Immediately
after
(Punch
sensors are
Extend
tie
activated
Duration)
Figure 23
19
IT8000 3/8" TIE-LOK DATA TOOL
IT7000 1/4" TIE-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Reset
Cut-off
trigger
60 ms
Immediately
150 ms (Cut
after punch
Retract
retract
Delay)
Document # P80080 Rev. C.3
BAND-IT-IDEX, Inc. 2024
Eject
Auto Eject
Only*
(0.5 s)