Error Codes - Band-it IT7000 User Manual

Table of Contents

Advertisement

User Manual

ERROR CODES

Types of Error Messages:
Warning Messages: These message types are displayed to assist operators with understanding tool behavior
and typically resolve themselves. These can be set to persist if the cycle is ended by the operator before they
resolve, depending on the "Enable Error Bypass" setting. They do not count toward Failed clamp counts. All
warning type errors will begin with a "3".
Error Messages: These do not stop the sequence and the tool can complete an installation when these occur,
but they may mean that the tool has not installed the band to the right specifications. Error messages will persist
when the "Enable Error Bypass" setting is not checked. These message types will increment the "Error Codes"
counter. All error messages begin with a "2".
Critical Alarms: When these errors occur, the tool cannot continue to operate normally, the tool will not
complete the installation and the tool will enter the faulted state. Critical alarms will always be displayed
independent of the "Enable Error Bypass" setting and require the user to address the issue or reset the error
before the tool can continue operation. The first digit of critical alarms begins with a "1".
Troubleshooting: In event of failure, cut all power, depress e-stop button, and contact authorized/appropriate
personnel to address the situation.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
53
IT8000 3/8" TIE-LOK DATA TOOL
IT7000 1/4" TIE-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved