Band-it GRSM17 Owner's Manual And Operating Instructions

Pneumatic center punch tool

Advertisement

Quick Links

Owner's Manual
and Operating
Instructions
Page
2
3
4
5
6
7
8
9
10
11
12
13
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925

Table of Contents

Information
Safety Guidelines and Warranty
Installing Center Punch Clamps
1
GRSM17
Pneumatic
Center Punch
Tool
Document# P47050 Rev. -
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GRSM17 and is the answer not in the manual?

Questions and answers

Summary of Contents for Band-it GRSM17

  • Page 1: Table Of Contents

    Gripper Assembly Replacement/Service Parts Identification Air Connection Diagram Factory Services Document# P47050 Rev. - www.BAND-IT-IDEX.com BAND-IT-IDEX, Inc. © Copyright A Unit of IDEX Corporation BAND-IT-IDEX, Inc. 2008 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925 All rights reserved...
  • Page 2 Hose, fitting and clamps must be compatible with each other and the intended working environment. If in doubt, consult the hose or fitting manufacturer or call BAND-IT. Clamping objects other than hose require similar precautions.
  • Page 3: Tool Overview And Installation

    Tool Overview: • The GRSM17 has been designed to automatically tension, lock and cut-off scrap tails of CP style clamps. Type 201 Stainless Steel and Galvanized Carbon Steel, 5/8” wide CP style clamps can be easily installed on hose assemblies or objects chosen by the operator.
  • Page 4: Air System Requirements

    Filtration – Follow typical filtration requirements of air operated equipment. The BAND-IT supplied system includes a filter and lubricator. Lubrication - Use DTE 24 hydraulic oil (BAND-IT part # S31589), oil drip-rate is verified by cycling the machine. If one drop falls in sight glass within 10-25 cycles, the lubricator is correctly adjusted.
  • Page 5: Setting Controls

    Rule: Always approach pull-up pressure setting from below and hold pressure setting from above the recommended value. Set the speed control to blue for all BAND-IT 5/8” wide Center Punch Clamps. Set pull-up pressure: pull knob and turn clockwise to reach pull-up pressure. Approach pressure setting from below by increasing pressure.
  • Page 6 Choose correct material type and diameter clamp to best satisfy the needs of the application. Installation of two BAND-IT Center Punch Clamps per hose end is suggested. Place clamps over hose, then install fitting. Note the location of the fitting’s hose barbs in order to locate clamps between barbs for maximum fitting retention.
  • Page 7: Trouble Shooting Guide

    Remove, inspect, clean and lubricate or replace tripper plate. Document# P47050 Rev. - www.BAND-IT-IDEX.com BAND-IT-IDEX, Inc. © Copyright A Unit of IDEX Corporation BAND-IT-IDEX, Inc. 2008 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925 All rights reserved...
  • Page 8: Preventative Maintenance

    Center Punch Tool For best results and proper functioning of the GRSM17 air tool, a filter / lubricator must be used on the air supply or in line within 30 feet of the air tool. The warranty is voided if a filter / lubricator is not used.
  • Page 9: Center Punch Head Information

    Mounting screws, and Instructions M17098 Center Punch Head Complete Head, Replacement Document# P47050 Rev. - www.BAND-IT-IDEX.com BAND-IT-IDEX, Inc. © Copyright A Unit of IDEX Corporation BAND-IT-IDEX, Inc. 2008 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925 All rights reserved...
  • Page 10: Gripper Assembly

    Gripper Kit Includes one Gripper and two Gripper springs Document# P47050 Rev. - www.BAND-IT-IDEX.com BAND-IT-IDEX, Inc. © Copyright A Unit of IDEX Corporation BAND-IT-IDEX, Inc. 2008 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925 All rights reserved...
  • Page 11: Replacement/Service Parts Identification

    Limit Switch Caution! Do not disable Serial Number Location Document# P47050 Rev. - www.BAND-IT-IDEX.com BAND-IT-IDEX, Inc. © Copyright A Unit of IDEX Corporation BAND-IT-IDEX, Inc. 2008 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925 All rights reserved...
  • Page 12: Air Connection Diagram

    Air Connection Pneumatic Diagram Center Punch Tool Internal tubes are made of bulk part numbers. See chart below. When ordering individual replacement tubes, specify tool part number (GRSM17), tube part number, tube I.D. letter and tube length. LENGTH PART (INCHES) NUMBER...
  • Page 13: Factory Services

    Additional Factory Support and Tool Service: Factory Service is Available Users of the GRSM17 should have years of dependable production if the preventative maintenance procedures are followed as outlined in this manual. In addition to available service parts, BAND-IT has additional factory service available. Service charges in addition to parts replacement charges will be invoiced if tool is not covered by our warranty.