Overview; Quick Start Overview - Band-it IT7000 User Manual

Table of Contents

Advertisement

User Manual

OVERVIEW

The IT8000/IT7000 are designed to install 3/8" Tie-Lok® or 1/4" Tie-Lok® ties with repeatability and
control. The machine is adjustable for individual applications and provides data to ensure the quality of
the finished assembly
The IT8000/IT7000 is powered by pneumatic cylinders and an electric motor powered with an AC
connection. Data is transferred from tool to controller (Siemens PLC) and can be extracted utilizing USB
or ethernet
The mechanical drive portion of the tool tensions, dimples, and cuts a clamp to form a durable and
strong fastened joint between two objects
The electronic control of the tool uses feedback from the mechanical portion to accurately control the
tension process of the tool and activate the punch and cut
The tool can be programmed by the user to accommodate specific applications utilizing the HMI
(Human-Machine Interface)
The tool can provide a data output to allow for verification of the integrity of the finished assembly

QUICK START OVERVIEW

1.
Connect data and motor cable to tool (Page 16)
2.
Connect data cable to controller (Page 17)
3.
Connect air harness to tool (Page 18) and controller (Page 18, Fig. 22)
4.
Connect HMI (touchscreen) to controller (page 17)
5.
Connect external regulator to controller (page 17)
6.
Connect air hose to external controller regulator (page 17)
7.
Plug in controller (120V US or 230V EU standard outlet)
8.
Power on tool, ensure door latch is set to "On" and flip power switch on outlet module (Page 17)
9.
HMI will boot up main program screen
10.
Enter tool serial number, located by the three mounting holes (Page 20)
11.
Tool is factory set to recommended settings for the IT8000 and .019" band thickness (punch pressure)
1. Ensure all settings are correct for application (page 32) and input settings as necessary
12.
Message banner at top of screen should read "Tool Ready" and the tool is ready to use (if trigger is
unresponsive press the "Reset Error" button on the HMI)
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Note: Ensure controller power and air are off before connecting to the tool (Page 16)
Customer supplied: connect with either 3/8" OD push-to-connect fitting or ¼" NPT thread
Note: If the controller is not getting power, ensure the internal circuit breaker is flipped on
1. Set punch pressure (Page 18)
2. Set target torque (Page 32)
3. Set error passcode preference (Page 40)
Note: The controller needs approximately 30 seconds to boot up before the trigger is responsive
8
IT8000 3/8" TIE-LOK DATA TOOL
IT7000 1/4" TIE-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itc800It8000

Table of Contents