AIR SYSTEM SETUP AND PRESSURE SETTINGS

C
aution: Pressures above the specified settings may cause premature clamp failure and/or tool wear.
Use the external regulators to adjust the air pressure on the tool. The system pressure regulator is in-line with
the Input Air line (Fig 19). It has two connectors that must be attached to power and read the regulator. The
punch pressure regulator is in-line with Punch Extend line (Fig. 21). The punch must be extended to read the
pressure. The punch pressure reading is shown on the manual screen. (pg. 35). The regulators are adjusted
independently. Note that the HMI pressure limits may need to be updated as well (pg. 38), but the pressure
cannot be adjusted in the HMI. The system pressure regulator has a 3/8" OD push-to connect fitting on it. If a
different style of fitting is preferred to connect to the input regulator, the fitting can be removed and replaced
with a different ¼" NPT fitting.
The controller and tool harness air-line valve numbering is shown below.
Valve Position
1
2
3
4
5
6
Figure 21
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Table 3 - Recommended Pressure Settings:
Tool
Tie Thickness
(in)
IT8000
0.019
IT8000
0.024
IT7000
0.014
Actuator
Punch Extend
Cut Extend
Trigger Extend
Clamp Extend
Punch Retract
Cut Retract
Table 4
Punch Pressure
(psi)
65 ± 2
80 ± 2
60 ± 2
Controller Pneumatics Valve
Bank
1
2
Unused
5
6
18
IT8000 3/8" TIE-LOK DATA TOOL
IT7000 1/4" TIE-LOK DATA TOOL
ITC800 CONTROL SYSTEM
System Pressure
(psi)
80 ± 5
80 ± 5
80 ± 5
Tool Air Harness
Figure 20
Exhaust
4
3
Exhaust
Figure 22
Document # P80080 Rev. C.3
BAND-IT-IDEX, Inc. 2024
Input
Air
© Copyright
All rights reserved