Komatsu GALEO HM350-2 Operation & Maintenance Manual page 214

Articulated dump truck
Hide thumbs Also See for GALEO HM350-2:
Table of Contents

Advertisement

MAINTENANCE
REPLACE ELEMENT
When pulling out the air cleaner element, make sure that you are standing on a firm place. If your footing is not secure when you
carry out the operation, there is danger of falling and suffering injury.
1. Stop the engine.
2. Remove 6 hooks (5) of dust cup (4), then remove the dust cup.
3. Hold outer element (6) with both hands, and move it up and
down and to the left and right while pulling it out.
4. Hold inner element (7) so that it does not come out, and clean
the inside of the air cleaner body with a dry cloth.
5. Use a dry cloth or compressed air to clean off the dirt stuck to
dust cup (4) and vacuator valve (8).
6. Check that there are no cracks in the lip of the vacuator valve
(8). If any cracks are found, replace with a new part.
7. Pull out inner element (7) and install a new inner element.
8. Install outer element (6) in the air cleaner body.
WARNING
SERVICE PROCEDURE