Before Commissioning; General; Proper Use; Setup Regulations - Fronius PlasmaModule 10 Operating Instructions Manual

Hide thumbs Also See for PlasmaModule 10:
Table of Contents

Advertisement

Available languages

Available languages

Before commissioning

General

Operating the equipment incorrectly can cause serious injury and damage.
Do not use the functions described here until you have fully read and understood the fol-
lowing documents:

Proper use

The digital PlasmaModule 10 is intended to be used only in conjunction with a suitable
TIG power source and a suitable plasma torch (e.g. Fronius PTW 1500).
The following plasma welding processes can be carried out using the PlasmaModule 10:
-
-
-
-
Any use above and beyond this purpose is deemed improper. The manufacturer shall not
be held liable for any damage arising from such usage.
Proper use also includes:
-
-

Setup regulations

The device is tested to IP23 protection, meaning:
-
-
The device can be set up and operated outdoors in accordance with IP23. However,
direct wetting (e.g. from rain) should be avoided.
Toppling or falling devices can cause life-threatening injuries.
Place devices on a solid, level surface so that they remain stable.
The venting duct is a very important safety feature. When choosing the device location,
ensure that the cooling air can enter and exit unhindered through the air ducts on the
front and back of the device. Electrically conductive metallic dust (from grinding work, for
example) must not be allowed to get sucked into the machine.

Mains connection

The devices are designed to run on the mains voltage shown on the respective rating
plates. If your version of the device does not come with mains cables and plugs ready-
fitted, these must be fitted in accordance with national regulations and standards. For
details of fuse protection of the mains lead, please see the technical data.
72
WARNING!
These operating instructions
all the operating instructions for the system components, especially the safety rules
Microplasma (sheet thicknesses from 0.2 - 0.8 mm / 0.01 - 0.03 in.)
Soft plasma welding (sheet thicknesses from 0.4 - 3.0 mm / 0.02 - 0.12 in.)
Plasma keyhole welding (sheet thicknesses from 3.0 - 10.0 mm / 0.12 - 0.39 in.)
Plasma brazing
Complying with all the instructions in the operating instructions
performing all stipulated inspection and maintenance work
protection against penetration by solid foreign bodies with diameters > 12 mm (0.47
in.)
protection against spraywater at any angle up to 60° to the vertical
WARNING!

Advertisement

Table of Contents
loading

Table of Contents