Safety Measures
The cell for the LaserHybrid welding process must meet the following require-
at the Installa-
ments:
tion Location
-
-
-
A toppling device can be deadly! Set up the device securely on an even, solid sur-
face
-
Special regulations apply in areas at risk of fire or explosion
-
Use instructions and checks within the company to ensure that the vicinity of the
workplace is always clean and organized.
Only set up and operate the device in accordance with the degree of protection
shown on the rating plate.
When setting up the device, ensure an all-round clearance of 0.5 m (1 ft. 7.69 in.)
so that the cooling air can enter and leave unhindered.
Take care to ensure that the applicable national and regional guidelines and acci-
dent prevention regulations are observed when transporting the device, espe-
cially guidelines concerning hazards during transport and shipment.
Before transporting the device, always completely drain the coolant and dis-
mantle the following components:
-
-
-
It is essential to conduct a visual inspection of the device to check for damage
after it has been transported but before it is commissioned. Have any damage re-
paired by trained service technicians before commissioning the device.
Safety Measures
Only operate the LaserHybrid head if all protective and safety devices are fully
in Normal Oper-
functional. If the safety devices are not fully functional, there is a risk of
ation
-
-
-
Safety devices that are not fully functional must be repaired before the device is
switched on.
Never bypass or disable safety devices.
Before conditioning the LaserHybrid head, ensure that no one can be put in
danger.
The LaserHybrid head must be examined at least once a week for externally de-
tectable damage and functionality of the safety devices.
12
be light-proof in relation to surrounding rooms
is shielded with at least 1 mm steel plate and/or approved laser protective
glass to protect against UV and laser beams
The laser welding process and the arc welding process must be stopped
automatically and immediately as soon as the cell is opened.
A tilt angle of no more than 10° is permitted
Follow the appropriate national and international regulations.
Wirefeeder
Wirespool
Shielding gas cylinder
injury or death to the operator or a third party,
damage to the device and other material assets belonging to the operating
company,
inefficient operation of the device.