Adjustment Devices On The Laser Welding Head - Fronius LaserHybrid WF 25i Operating Instructions Manual

Hide thumbs Also See for LaserHybrid WF 25i:
Table of Contents

Advertisement

Adjustment
The laser welding head is equipped with adjustment devices, which allow for pre-
devices on the
cise positioning in the x, y, and z coordinate axes:
laser welding
head
(3)
(4)
(5)
(6)
76
Adjustment screw with graduation for the x axis
Adjustment range +7/-2 mm
Allen screw size 5 mm
¼-turn corresponds to an adjustment path of 0.25 mm
Reading accuracy using vernier scale 0.1 mm
Scale for the x axis
Scale for additional adjustment option in the z axis
Adjustment range 0/+10 mm
Basic position for the Trumpf optics support = 0
For the additional adjustment in the z axis, loosen the two Allen screws
size 5 mm and move the optics support.
Tightening torque for Allen screws = 10 Nm
Adjustment screw with graduation for the z axis
Adjustment range +12/-7 mm
Allen screw size 5 mm
¼-turn corresponds to an adjustment path of 0.25 mm
Reading accuracy using vernier scale 0.1 mm
(1)
Scale for the z axis
(1)
(2)
Adjustment screw with gradu-
(2)
ation for the y axis
Adjustment range +/- 4.5 mm
Allen screw size 5 mm
(3)
¼-turn corresponds to an ad-
(4)
justment path of 0.25 mm
(5)
(6)