Power consumption
Typical power consumption
Communication interface
Minimum temperature rating of the
cable to be connected to the field
wiring terminals:
MDC büS/CANopen with on/off valve Type 6013
Operating voltage
Power consumption
Typical power consumption
Communication interface
Electrical connections
Minimum temperature rating of the
cable to be connected to the field
wiring terminals:
MDC Industrial Ethernet with on/off valve Type 6724
Operating voltage
Power consumption
Typical power consumption
Communication interface
Electrical connections
Minimum temperature rating of the
cable to be connected to the field
wiring terminals:
MDC büS/CANopen with on/off valve Type 6724
Operating voltage
Power consumption
Typical power consumption
Communication interface
Electrical connections
22
< 16 W
8 W for water and at a flow rate of 25 kg/h
Industrial Ethernet: PROFINET, EtherNet/IP, EtherCAT, Modbus TCP
75 °C
24 V DC ±10 %
residual ripple < 2 %
< 16 W
8 W for water and at a flow rate of 25 kg/h
büS and CANopen. The communication type can be chosen with the
Bürkert Communicator software.
M12 plug 5-pin A-coding
75 °C
24 V DC ±10 %
residual ripple < 2 %
< 3 W
3 W for water and at a flow rate of 25 kg/h
Industrial Ethernet: PROFINET, EtherNet/IP, EtherCAT, Modbus TCP
M12 plug 5-pin A-coding
2 M8 socket 4-pin D-coding
service büS interface
75 °C
24 V DC ±10 %
residual ripple < 2 %
< 3 W
3 W for water and at a flow rate of 25 kg/h
büS and CANopen. The communication type can be chosen with the
Bürkert Communicator software.
M12 plug 5-pin A-coding
Type 8756 Batch
Technical data