Reference Manual
00809-0100-4101
AMS device manager applying a user configuration
Any amount of user configurations can be created for the application. They can also be
saved, and applied to connected devices or to devices in the Device List or Plant Database.
Note
When using AMS Device Manager Revision 6.0 or later, the device to which the user
configuration is applied, must be the same model type as the one created in the user
configuration. When using AMS Device Manager Revision 5.0 or earlier, the same model
type and revision number are required.
To apply a user configuration perform the following procedure:
Procedure
1. Select the desired user configuration in the User Configurations window.
2. Drag the icon onto a like device in AMS Device Manager Explorer or Device
3. Transfer parameters from the user configuration to the target device as desired,
3.11.2 
Burst mode
When configured for burst mode, the 2051 provides faster digital communication from
the transmitter to the control system by eliminating the time required for the control
system to request information from the transmitter. Burst mode is compatible with the
analog signal. Because the HART
transmission, the analog value can drive other equipment in the loop while the control
system is receiving the digital information. Burst mode applies only to the transmission
of dynamic data (pressure and temperature in engineering units, pressure in percent
of range, and/or analog output), and does not affect the way other transmitter data is
accessed.
Access to information other than dynamic transmitter data is obtained through the normal
poll/response method of HART communication. A HART Communicator, AMS Device
Manager or the control system may request any of the information that is normally
available while the transmitter is in burst mode. Between each message sent by the
transmitter, a short pause allows the HART Communicator, AMS Device Manager or a
control system to initiate a request. The transmitter will receive the request, process the
response message, and then continue "bursting" the data approximately three times per
second.
HART communicator
Table 3-19: Fast keys
4-20 mA Fast Keys
1-5 Vdc Fast Keys
AMS device manager
Right-click on the device and select Configure from the menu.
Reference Manual
Connection View. The Compare Configurations window opens, showing the
parameters of the target device on one side and the parameters of the user
configuration on the other.
Click OK to apply the configuration and close the window.