Transporter replacement
Table of Contents

Advertisement

TFinity Transporter Replacement
6. Close and latch the full-length access door on the back of the service
7. Return to the front of the library and click OK to confirm that the safety
8. Click OK in response to the safety door closed status message.
November 2018
b. Using the handle, carefully slide the door toward you, into its open
position.
Figure 40 Slide the service bay safety door toward you to its
open position.
c. Lift the handle to its vertical position and use the captive screw to
secure it to the edge of the door.
frame where the TeraPorter is parked (see
the door, if desired.
door is open.
As soon as you confirm that the safety door is open, the library applies
power to the TeraPorter and puts it back into operation.
Transporter Replacement—Spectra TFinity Library
Complete the Replacement
Service door
Figure 6 on page
11). Lock
36