Command example:
ipmitool raw
ipmitool raw
Table 2: 'Read Configuration Settings' Command
This command is used to change System Event Log (SEL) behaviour when the SEL runs full. Two
options are available: stop logging when the SEL is full, or roll over (overwrite oldest event in
case of new event). This rule is applied to subsequent entries being written to the SEL.
Request
Byte Data Field
Response
Byte Data Field
_20220127_JH.DOCX
User Manual_FWA-6171
Command Sequence
>ipmitool raw 0x2e 0x41 0x39 0x28 0x00
0x04 0x03
39 28 00 01
>ipmitool raw 0x2e 0x41 0x39 0x28 0x00
0x04 0x03
39 28 00 00
4.1.4

Advantech OEM Command 'SEL Mode Configuration

1
NetFn: 0x2e
2
Cmd: 0x62
3
IANA Byte 1: 0x39
4
IANA Byte 2: 0x28
5
IANA Byte 3: 0x00
6
SEL Mode
[7:0]:
00h: Stop on full. BMC will not log any new event to SEL.
01h: Wrap around when full. BMC will overwrite the oldest event
with a new incoming event.
1
Completion Code
00h: command completed normally
Copyright
2017
Advantech Co. Ltd. All rights reserved.
Description
Get "Keep PHY
Link Up" status
Status is enabled
Get "Keep PHY
Link Up" status
Status is disabled