Advantech Oem Command 'Read Port 80 (Bios Post Code) - Advantech FWA-6171 User Manual

2u rackmount network appliance
Table of Contents

Advertisement

Command example:
ipmitool raw
Please note that the setting of the SEL full action (Do Nothing or Erase Immediately options) in the
BIOS setup menu (under the submenu: Platform -> Platform Management -> System Event Log ->
When SEL is Full) is a parallel mechanism that only applies to BIOS writing events to the SEL.
BMC Setting
Stop on full
Wrap around
when full
Wrap around
when full
-
-
This command is used to retrieve the latest BIOS POST Code.
Request
Byte Data Field
_20220127_JH.DOCX
User Manual_FWA-6171
2
IANA Byte 1: 0x39
3
IANA Byte 2: 0x28
4
IANA Byte 3: 0x00
5
SEL Mode
[7:0]:
00h: stop on full
01h: wrap around when full
Command Sequence
>ipmitool raw 0x2e 0x62 0x39 0x28 0x00 0x01
39 28 00
BIOS Setting
Result
Do Nothing
Will not log new event to SEL
Do Nothing
Overwrite the oldest event on SEL
Erase
Overwrite the oldest event on SEL
Immediately
4.1.5

Advantech OEM Command 'Read Port 80 (BIOS POST Code)

1
NetFn: 0x2e
2
Cmd: 0x80
3
IANA Byte 1: 0x39
Copyright
2017
Advantech Co. Ltd. All rights reserved.
Description
Set SEL full action
as "Stop on full"