Step 3. Install PCIe module on main board with screw as arrow indicate.
1.6

Optimum Mounting Environment

Please always keep 20cm space around platform for better thermal dissipation if not running FWA-6171 on
rack.
Please make sure environment condition before power on this system:
Operating temperature 0 ~ 40 °C (32 ~ 104 °F) with air flow speed 0.7 m/sec
Non-operating Temperature -20 ~ 80° C (-4 ~ 167° F)
Relative humidity 95% @ 40° C (non-condensing)
Storage temperature -40 ~ 85° C (-40 ~ 185° F)
FWA-6171 AC/DC power source as follow:
AC 100-127V/10A
AC 200-240V/6A (FWA-6171 w/ 1300W PSU)/ AC 200-240V/5A (FWA-6171L w/850W PSU)
AC 100-240VAC~, 12-7A (FWA-6171 w/ 1200W PSU)
DC -48 - -60V/21A or 24A MAX