Technical Data

7.
TECHNICAL DATA
7.1.

Conformity and standards

In accordance with the EC Declaration of conformity, the device is
compliant with the EC Directives.
Several approvals such as FDA, EC Regulation No 1935/2004, USP,
ATEX and others can be provided, depending on the characteristics
of the ordered device.
7.2.

Type label

Type label for Type 2380 (by the cap of the device, see „Fig. 1" or
„Fig. 2").
Control function
Controller type
Orifice
Valve type
Sealing material
Type Body material
Fig. 3:
Type label 2380 - example
Type 2380
Several features of type code
Pressure of medium in bar(g)
Control air pressure in bar(g)
Operating voltage / if applicable communication
ID-No.
Serial no. S/N
Date of manufacture (encoded)
QR code CE (or other) marks
7.3.

Operating conditions

WARNING!
Risk of injury by ignoring the permitted operating
conditions!
Important device-specific technical specifications are indi-
cated on the type label.
▶ Observe permitted operating conditions printed on the
device type label.
Ambient temperatures -10 ... +55 °C
Media
liquids and gases
(ultrapure, sterile, dirty, aggressive,
abrasive or even highly viscous),
steam for sterilization only
Media temperatures
0 ... +80 °C
(-10 °C ... +150 °C at limited ope-
rating conditions
Media pressure
vacuum ... 6 bar(g)
*) m edia pressure max. 4 bar(g),
up to +134 °C: max. 60 min, 2380-LA: ambient temperature max. +40 °C,
up to +150 °C: max. 30 min, 2380-LA: ambient temperature max. +35 °C