4

TECHNICAL DATA

4.1

Standards and directives

The device complies with the valid EU harmonisation legislation. In addition, the device also complies with
the requirements of the laws of the United Kingdom.
The harmonised standards that have been applied for the conformity assessment procedure are listed in
the current version of the EU Declaration of Conformity/UK Declaration of Conformity.
4.2

Approvals

Approvals and conformities are only valid if the labelling is on the device.
Labelling on device
Tab. 2: Approvals
4.3

Operating conditions

Medium
Medium temperature
Ambient temperature
Storage temperature
Operating mode
Installation position
Degree of protection (EN 60529 / IEC 60529)
Materials
Viscosity
12
Certification
The device is ATEX approved.
Labelling for approval for use in potentially explosive areas is on the device.
Valid for coils: UL-recognized
The coils are recognised by UL in the USA and Canada according to:
UL 429 (electrically operated valves)
CAN/CSA-C22.2 No. 139
Type 6211
Technical data
neutral, gaseous and liquid media which do not at-
tack the body and seal materials. See resistance
chart at
country.burkert.com
NBR: 0 °C...+70 °C (with PPE/PA body 0 °C...50 °C)
EPDM: −10 °C...+70 °C (with PPE/PA body
−10 °C...+50 °C)
FKM: 0 °C...+70 °C (with PPE/PA body
0 °C...+50 °C)
0 °C...+55 °C
0 °C...+50 °C with PPE/PA body
−40...+80 °C
Continuous operation (unless otherwise stated on
the type label)
Any, preferably actuator face up
IP65*
*With correctly connected cable plug.
see data sheet
2
maximum 21 mm
/s