I Technical Specifi Cati Ons - Zodiac eXO iQ Series Instructions For Installation And Use Manual

Salt water chlorinator, ph/redox regulation
Hide thumbs Also See for eXO iQ Series:
Table of Contents

Advertisement

1.2 I Technical specifi cati ons

1.2.1 Salt water chlorinator
Nominal chlorine producti on
Nominal output current
Standard
Recommended salt
salinity
level - minimum salt
Low salinity
level
(LS)
Supply voltage
Electrical power
Protecti on rati ng
Cell throughput (minimum/
maximum)
Maximum allowable pressure in
the cell
Operati ng water temperature
Frequency bands
Radio output power
1.2.2 Opti onal pH Link or Dual Link module
Supply voltage
Peristalti c pump fl ow rate
Maximum back pressure (injecti on)
pH and ORP sensor type
pH correcti on
pH minus dispensing
pH sensor calibrati on
ORP sensor tolerances
ORP sensor calibrati on
Sensor cable length
eXO® (iQ) 10
eXO® (iQ) 18
GenSalt OT 10
GenSalt OT 18
10 g/h
18 g/h
2.8 A
3.6 A
eXO®(iQ): 4 g/L - 3.3 g/L min.
GenSalt OT: 3.0 g/L min.
2 g/L - 1.6 g/L min.
2.400 GHz - 2.497 GHz
pH Link
Extra-low voltage (connected to the control box)
Combined (pH=blue/ORP=yellow)
pH minus only (hydrochloric acid or sulphuric acid)
1 point or 2 points (pH 4 and pH 7)
/
eXO® (iQ)
GenSalt OT
22
25
22 g/h
25 g/h
5 A
5 A
/
110 - 240V
50-60 Hz
200 W maximum
IP43
5m³/h < 18m³/h
2.75 bar
5°C < 40°C
+19.5 dBm
Dual Link
1.2 L/h
1.5 bar
Proporti onal cyclic
10 ppm maximum (shock
chlorinati on)
1 point (470 mV)
3 metres
eXO® (iQ)
35
35 g/h
7.2 A
EN
7

Advertisement

Table of Contents
loading