I Installing The Temperature Sensor (Depending On The Model) - Zodiac eXO iQ Series Instructions For Installation And Use Manual

Salt water chlorinator, ph/redox regulation
Hide thumbs Also See for eXO iQ Series:
Table of Contents

Advertisement

2.2 I Installing the temperature sensor (depending on the model)

• The water temperature sensor displays the water temperature value on the appliance screen and manages
chlorinati on according to the temperature. The sensor must measure the temperature of the water
upstream of any possible heati ng system.
• The sensor is designed to be mounted on rigid Ø50 mm, Ø63 mm or Ø1 ½'' PVC pipes. Do not install on any
other type of pipe.
• Install the sensor either between the fi lter pump and the fi lter, or between the fi lter and any other
downstream equipment, see "2.1 I Installing the cell":
Drill a hole in the pipe using a Ø9 mm (max. Ø10 mm) drill bit, then deburr the hole,
-
- Install the O-ring provided on the sensor body,
- Secure the sensor using the stainless-steel clamping collar provided. Do not use excess strength.
2.3 I Installing the fl ow switch
In cases where a pH Link or Dual Link module is used, the fl ow switch will be installed on the POD
Kit, see "3.3 I Installing the fl ow switch on the POD kit"
• The fl ow switch and its 50 mm diameter fi xture collar supplied as standard (63 mm diameter available
as a spare part) must be installed immediately before the cell and aft er any valves present (
threaded adapter and the Tefl on tape provided to install the fl ow switch on its fi xture collar.
• Screw the fl ow switch using using the clamping nut only (screw by hand!) (
Installati on on a by-pass
• Failure to comply with these instructi ons could lead to the destructi on of the cell! The
manufacturer cannot be held liable in this case.
• The fl ow switch has a directi on for installati on (arrow indicated on it showing the fl ow
directi on for the water). Make sure that it is correctly placed on its fi xture collar so that it
stops the appliance's producti on when fi ltering is stopped.
10
(chlorinator only without pH Link or Dual Link modules)
In-line installati on
: Sensor
:
O-ring
:
Stainless steel clamping
collar
).
Directi on of water
Clamping
nut
). Use the
fl ow

Advertisement

Table of Contents
loading

Table of Contents