RANGE HOOD USE
Range Hood Control Panel
Remote
Delayed
Control
Auto
Sensor
Shut Off
Light
Remote Control Sensor
The Remote Control Sensor receives infrared (IR)
•
signal from the remote control.
•
The maximum distance for IR data
transmission is 10 feet and requires direct line
of sight.
•
The transmission distance may vary
depending on the room temperature and the
condition of the battery in the remote control.
Delayed Auto Shut-Off
•
When the hood is operating in any speed,
touch the this button once will activate the
Delayed Auto Shut Off function.
Touch the Speed (-) or Speed (+) button to
•
choose a timer that suits your need the most.
•
Three preset timers to choose from: 5-min,
10-min and 15-min.
•
The timer will start immediately once it's set.
When it reaches 0, the Range Hood and the
Light will be turned off automatically.
Clock / Current Time Display
When the Delayed Auto Shut Off function is
•
not activated, the LCD Display will show the
current time of the day.
THE CLOCK CAN ONLY BE SET WHILE THE
BLOWER IS OFF.
•
To set the Clock:
Touch the Delayed Auto Shut Off button
•
once. The hour indicator will flash.
Touch the Speed (-) or Speed (+)button to
•
adjust to the desired hours (12-Hour).
•
When done setting the hour, touch the
Delayed Auto Shut Off button again. The
minute indicator will flash.
Touch the Speed (-) or Speed (+) button to
•
adjust to the desired minutes.
•
When done setting the minutes, touch the
Delayed Auto Shut Off button to confirm
all settings.
Touch the Light button to check and
•
validate the time.
•
When the Delayed Auto Shut Off fuction is
activated while the blower is running, a
countdown timer will show up in the LCD
Display.
Light
Touch the Light button once and the lamps will
•
turn on.
Touch the Light button again and the lamps will
•
Speed
turn off.
•
The Light button operates independently from
the Power button. It works even when the
range hood is not turned on.
•
Always turn off the lamps before powering off
the range hood.
The Delayed Auto Shut Off function will turn off
•
the Light automatically when the timer reaches
0.
Speed (-) (+)
•
While the range hood is off:
•
•
•
Power
Touch the Power button once while the range
•
hood is running to shut it off immediately.
WARNING
Read all instrutions and warnings before using
the hood.
•
DO NOT use the hood when there are no safety
grills and filters.
•
NEVER dispose cigarette ashes, ignitable
substances, or any foreign objects into blowers.
•
NEVER leave the cooking appliances
unattended. When frying, the oil in the pan
can easily overheat and catch on fire. The risk
of self-combustion is higher when the oil has
been used several times.
•
NEVER cook on "open" flames under the
range hood. Check deep-fryers during use:
Superheated oil may be flammable.
Touch the Speed (-) button to turn on the
Range Hood on the highest speed (F4).
Touch the Speed (+) button to turn on the
Range Hood on the lowest speed (F1).
Touch (-) or (+) again to change the blower
speed as indicated in the LCD Display until
the desired speed is reached.
9