Download Print this page

Awoco RH-C06-FC Owner's Manual

6" height under cabinet series range hood

Advertisement

Quick Links

awoco.com
6" Height
Under Cabinet Series
RH-C06 Models
6" Top
Round Adapter
* The adapters are interchangeable between RH-C06 & RH-R06 models.
* Contact us if you wish to exchange your existing adapter to a different one.
* Unpack & Check for Shipping Damages *
Air Damper
3-1/4" x 10" Top
Rectangular Adapter
* Test Run Before Installation *
Range Hood
OWNER'S
MANUAL
Manual Version:
For Models:
RH-R06 Model
Caution !
Make sure the air damper can
open freely after the installation.
3-1/4" x 10" Rear
Rectangular Adapter
2024A
RH-C06-FC
RH-R06-FC

Advertisement

loading
Need help?

Need help?

Do you have a question about the RH-C06-FC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Awoco RH-C06-FC

  • Page 1 Range Hood awoco.com OWNER'S MANUAL 6" Height Manual Version: 2024A For Models: RH-C06-FC Under Cabinet Series RH-R06-FC RH-C06 Models RH-R06 Model Caution ! Air Damper Make sure the air damper can open freely after the installation. 6" Top 3-1/4" x 10" Top 3-1/4"...
  • Page 2: Installation Overview

    This manual provides a general insight on the installation and may not include solutions for all possible issues that may occur. In case of this manual destroyed or lost, please visit https:/ /www.awoco.com and download a digital version.
  • Page 3: Table Of Contents

    Important Safety Instructions Installation Preparations Venting Requirements Venting System Setup Minimum Duct Size Electrical Requirement Installation Installing the Range Hood Connecting the Vent System Electrical Connection Installing the Baffle Filters Installing the Oil Collector Completing the Installation Range Hood Use Range Hood Control Panel Range Hood Care Clean the Exterior Surfaces...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS TO REDUCE THE RISK OF FIRE, ELECTRIC low or medium settings. SHOCK OR PERSONAL INJURY, PLEASE • Always turn the hood ON when cooking at READ THE FOLLOWING CAREFULLY BEFORE high heat or when flambeing food (i.e. Crepes ATTEMPTING TO ASSEMBLE, INSTALL, Suzette, Cherries Jubilee, Peppercorn Beef OPERATE OR MAINTAIN THE RANGE HOOD:...
  • Page 5: Installation Preparations

    INSTALLATION PREPARATIONS VENTING REQUIREMENTS DO NOT • Have the venting system go vertically from • End the venting system in an enclosed area the range hood to the roof if possible. indoors. • Have 24"-30" distance between the cooktop • Use plastic vent.
  • Page 6: Minimum Duct Size

    INSTALLATION PREPARATIONS Rear Venting in-Wall Exhaust Duct Damper Rear Cabinet Adapter Range Hood Caution ! • The fully opened Air Damper might block the air IMPORTANT! flow. Stove Top • Remove the Air Damper first Observe all governing codes and ordinances. before connecting the duct to the Rear Adapter.
  • Page 7: Installation

    INSTALLATION This range hood series can be: the bottom of the cabinet through the knockout holes shown below: • Installed under the cabinet ONLY. 1. Installing the Range Hood Under the Cabinet • For installing under the cabinet with recessed bottom, attach a 4"...
  • Page 8: Installing The Baffle Filters

    INSTALLATION • In case of a direct connection to the house 5. Installing the Oil Collector wiring is preferred, do the following: Follow the instruction in Page 10 to install the • Disconnect the power. • • Cut off the plug from the power cord. Oil Collector.
  • Page 9: Range Hood Use

    RANGE HOOD USE RANGE HOOD CONTROL PANEL POWER Light Speed Power • Press the Power button once and the Range Hood will be activated in standby mode, then press one of the Speed buttons to set the speed of the Range Hood. •...
  • Page 10: Range Hood Care

    Repeat • This range hood uses 12V, 2W LED. these steps until there's no oil residue remains. Contact Awoco customer service to get the • Let the filters dry thoroughly. replacement LED lights.
  • Page 11 RANGE HOOD CARE Remove Baffle Filters • Reach into the Hood Unit and push the Lamp out from the inside of the Hood Unit. Push the lamp out • Disconnect the wires. • Connect the wires to the new Lamp. •...
  • Page 12: Range Hood Troubleshooting

    RANGE HOOD TROUBLESHOOTING Before Calling for Service Issue Possible Cause / Solution If the air damper does not open freely when the hood turns on, the smoke can't be sucked out. The air damper does not open after • Remove the duct attached to the hood, clear any debris that installation are blocking the air damper, and make sure that the air damper can open freely before reconnecting the duct.
  • Page 13: Warranty

    • Repair parts or replacement products will be provided by Awoco, free of charge, on an • Contact us at 1-888-412-3428, between 10 exchange basis, and will be either new or AM and 5 PM, Monday - Friday, Pacific Time.
  • Page 14 Website: www.awoco.com Customer Support: 1-888-412-3428 Email: sales@awoco.com...